List of Parameters
Parameters
1-403
© Siemens AG 2009 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009
Description:
Setting parameter for the run-time group in which instance PLI 0 of the polyline is to be called
Value:
5:
Run-time group 5
6:
Run-time group 6
9999: Do not calculate
Description:
Setting parameter for the run sequence of instance PLI 0 within the run-time group set in p20376.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description:
Sets the signal source for input X of the polyline (20 breakpoints) of instance PLI 1.
Description:
Display parameter for the output quantity Y of the polyline (20 breakpoints) of instance PLI 1
p20376
PLI 0 run-time group / PLI 0 RTG
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
T
Scaling:
-
Data set:
-
Min Max Factory
setting
5 9999
9999
p20377
PLI 0 run sequence / PLI 0 RunSeq
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
T
Scaling:
-
Data set:
-
Min Max Factory
setting
0 32000
980
p20378
CI: PLI 1 input X / PLI 1 input X
Access level:
3
Calculated:
-
Data type:
U32 / FloatingPoint32
Can be changed:
T
Scaling:
PERCENT
Data set:
-
Min Max Factory
setting
- - 0
r20379
CO: PLI 1 output Y / PLI 1 output Y
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Unit:
-
Scaling:
PERCENT
Data set:
-