Command and Drive Data Sets – Overview
Parameters
1-411
© Siemens AG 2009 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009
p2286[0...n]
BI: Hold technology controller integrator / Tec_ctr integ stop
p2289[0...n]
CI: Technology controller pre-control signal / Tec_ctrl prectrl
p2296[0...n]
CI: Technology controller output scaling / Tec_ctrl outp scal
p2297[0...n]
CI: Technology controller maximum limit signal source / Tec_ctrl m_lm s_sc
p2298[0...n]
CI: Technology controller minimum limit signal source / Tec_ctrl min_l s_s
p2299[0...n]
CI: Technology controller limit offset / Tech_ctrl lim offs
p3111[0...n]
BI: External fault 3, enable / Ext fault 3 enab
p3112[0...n]
BI: External fault 3 enable negated / Ext flt 3 enab neg
p3230[0...n]
CI: Load monitoring, speed actual value / Load monit n_act
p3232[0...n]
BI: Load monitoring failure detection / Load_moni fail_det
1.3.2
Drive Data Sets (DDS)
Product: SINAMICS G120, Version: 4301300, Language: eng, Type: DDS
p0340[0...n]
Automatic calculation, motor/control parameters / Calc auto par
p0640[0...n]
Current limit / Current limit
p1001[0...n]
CO: Fixed speed setpoint 1 / n_set_fixed 1
p1002[0...n]
CO: Fixed speed setpoint 2 / n_set_fixed 2
p1003[0...n]
CO: Fixed speed setpoint 3 / n_set_fixed 3
p1004[0...n]
CO: Fixed speed setpoint 4 / n_set_fixed 4
p1005[0...n]
CO: Fixed speed setpoint 5 / n_set_fixed 5
p1006[0...n]
CO: Fixed speed setpoint 6 / n_set_fixed 6
p1007[0...n]
CO: Fixed speed setpoint 7 / n_set_fixed 7
p1008[0...n]
CO: Fixed speed setpoint 8 / n_set_fixed 8
p1009[0...n]
CO: Fixed speed setpoint 9 / n_set_fixed 9
p1010[0...n]
CO: Fixed speed setpoint 10 / n_set_fixed 10
p1011[0...n]
CO: Fixed speed setpoint 11 / n_set_fixed 11
p1012[0...n]
CO: Fixed speed setpoint 12 / n_set_fixed 12
p1013[0...n]
CO: Fixed speed setpoint 13 / n_set_fixed 13
p1014[0...n]
CO: Fixed speed setpoint 14 / n_set_fixed 14
p1015[0...n]
CO: Fixed speed setpoint 15 / n_set_fixed 15
p1030[0...n]
Motorized potentiometer configuration / Mop configuration
p1037[0...n]
Motorized potentiometer maximum speed / Mop n_max
p1038[0...n]
Motorized potentiometer minimum speed / Mop n_min
p1040[0...n]
Motorized potentiometer starting value / Mop start value
p1047[0...n]
Motorized potentiometer ramp-up time / Mop ramp-up time
p1048[0...n]
Motorized potentiometer ramp-down time / Mop ramp-down time
p1058[0...n]
Jog 1 speed setpoint / Jog 1 n_set
p1059[0...n]
Jog 2 speed setpoint / Jog 2 n_set
p1063[0...n]
Speed limit setpoint channel / n_limit setp
p1080[0...n]
Minimum speed / Minimum speed
p1082[0...n]
Maximum speed / n_Max
p1083[0...n]
CO: Speed limit in positive direction of rotation / n_limit pos
p1086[0...n]
CO: Speed limit in negative direction of rotation / n_limit neg
p1091[0...n]
Skip speed 1 / n_skip 1
p1092[0...n]
Skip speed 2 / n_skip 2
p1093[0...n]
Skip speed 3 / n_skip 3
p1094[0...n]
Skip speed 4 / n_skip 4
p1101[0...n]
Skip speed bandwidth / n_skip bandwidth
p1120[0...n]
Ramp-function generator ramp-up time / RFG ramp-up time
p1121[0...n]
Ramp-function generator ramp-down time / RFG ramp-down time