List of Parameters
Parameters
1-269
© Siemens AG 2009 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009
Description:
Sets the value for fixed value 1 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
Description:
Sets the value for fixed value 2 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
Description:
Sets the value for fixed value 3 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
Description:
Sets the value for fixed value 4 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
Description:
Sets the value for fixed value 5 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p2201[0...n]
CO: Technology controller, fixed value 1 / Tec_ctrl fix val 1
Access level:
2
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
PERCENT
Data set:
DDS, p0180
Min Max Factory
setting
-200.00 [%]
200.00 [%]
10.00 [%]
p2202[0...n]
CO: Technology controller, fixed value 2 / Tec_ctrl fix val 2
Access level:
2
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
PERCENT
Data set:
DDS, p0180
Min Max Factory
setting
-200.00 [%]
200.00 [%]
20.00 [%]
p2203[0...n]
CO: Technology controller, fixed value 3 / Tec_ctrl fix val 3
Access level:
2
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
PERCENT
Data set:
DDS, p0180
Min Max Factory
setting
-200.00 [%]
200.00 [%]
30.00 [%]
p2204[0...n]
CO: Technology controller, fixed value 4 / Tec_ctrl fix val 4
Access level:
2
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
PERCENT
Data set:
DDS, p0180
Min Max Factory
setting
-200.00 [%]
200.00 [%]
40.00 [%]
p2205[0...n]
CO: Technology controller, fixed value 5 / Tec_ctrl fix val 5
Access level:
2
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
PERCENT
Data set:
DDS, p0180
Min Max Factory
setting
-200.00 [%]
200.00 [%]
50.00 [%]