List of Parameters
Parameters
1-391
© Siemens AG 2009 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009
Description:
Setting parameter for the run-time group in which instance DIF 0 of the differentiating element is to be called.
Value:
5:
Run-time group 5
6:
Run-time group 6
9999: Do not calculate
Description:
Setting parameter for the run sequence of instance DIF 0 within the run-time group set in p20287.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description:
Sets the signal source of input quantity I of instance NOT 4 of the inverter.
Description:
Display parameter for the inverted output of instance NOT 4 of the inverter.
Description:
Setting parameter for the run-time group in which the instance NOT 4 of the inverter is to be called.
Value:
1:
Run-time group 1
2:
Run-time group 2
3:
Run-time group 3
4:
Run-time group 4
5:
Run-time group 5
6:
Run-time group 6
9999: Do not calculate
Description:
Setting parameter for the run sequence of instance NOT 4 within the run-time group set in p20302.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
p20287
DIF 0 run-time group / DIF 0 RTG
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
T
Scaling:
-
Data set:
-
Min Max Factory
setting
5 9999
9999
p20288
DIF 0 run sequence / DIF 0 RunSeq
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
T
Scaling:
-
Data set:
-
Min Max Factory
setting
0 32000
750
p20300
BI: NOT 4 input I / NOT 4 input I
Access level:
3
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Data set:
-
Min Max Factory
setting
- - 0
r20301
BO: NOT 4 inverted output / NOT 4 inv output
Access level:
3
Calculated:
-
Data type:
Unsigned32
Unit:
-
Scaling:
-
Data set:
-
p20302
NOT 4 run-time group / NOT 4 RTG
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
T
Scaling:
-
Data set:
-
Min Max Factory
setting
1 9999
9999
p20303
NOT 4 run sequence / NOT 4 RunSeq
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
T
Scaling:
-
Data set:
-
Min Max Factory
setting
0 32000
770