Parameters
List of Parameters
1-200
© Siemens AG 2009 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009
Description:
Displays the torque generating current setpoint Iqset after the torque limits and the clock cycle interpolation is
ahead of the current setpoint filters.
Description:
Sets the smoothing time constant for the setpoint of the torque-generating current components.
Note:
The smoothing time does not become effective until the field-weakening range is reached.
Description:
Sets the scaling of the dynamic current controller pre-control for the flux-generating current component Isd.
Note:
The parameter is effective for permanent-magnet synchronous motors.
Description:
Sets the scaling of the dynamic current controller pre-control for the torque/force-generating current component Isq.
Description:
Sets the proportional gain of the current controller. This value is automatically preset using p3900 or p0340 when
commissioning has been completed.
Description:
Sets the integral-action time of the current controller.
Dependency:
Refer to: p1715
Description:
Displays the actual output of the Isq current controller (torque/force generating current, PI controller).
The value contains the proportional and integral components of the PI controller.
r1650
Current setpoint torque-generating before filter / Iq_set before filt
Access level:
4
Calculated:
-
Data type:
FloatingPoint32
Unit:
[Arms]
Scaling:
p2002
Data set:
-
p1654[0...n]
Curr. setpoint torque-gen. smoothing time field weakening range / Isq_s T_smth FW
Access level:
4
Calculated:
p0340 = 1
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Data set:
DDS, p0180
Min Max Factory
setting
0.1 [ms]
50.0 [ms]
4.8 [ms]
p1702[0...n]
Isd current controller pre-control scaling / Isd_ctr_prectrScal
Access level:
4
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Data set:
DDS, p0180
Min Max Factory
setting
0.0 [%]
200.0 [%]
70.0 [%]
p1703[0...n]
Isq current controller pre-control scaling / Isq_ctr_prectrScal
Access level:
4
Calculated:
p0340 = 1,3,4
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Data set:
DDS, p0180
Min Max Factory
setting
0.0 [%]
200.0 [%]
60.0 [%]
p1715[0...n]
Current controller P gain / I_ctrl Kp
Access level:
4
Calculated:
p0340 = 1,3,4
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Data set:
DDS, p0180
Min Max Factory
setting
0.000 100000.000
0.000
p1717[0...n]
Current controller integral-action time / I_ctrl Tn
Access level:
4
Calculated:
p0340 = 1,3,4
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Data set:
DDS, p0180
Min Max Factory
setting
0.00 [ms]
1000.00 [ms]
2.00 [ms]
r1718
CO: Isq controller output / Isq_ctrl outp
Access level:
4
Calculated:
-
Data type:
FloatingPoint32
Unit:
[Vrms]
Scaling:
p2001
Data set:
-