Setting parameter for the run sequence of instance RSR 2 within the run-time group set in p20327.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description:
Sets the signal source for trigger input I, D input D, set input S, and reset input R of instance DFR 2 of the D flipflop.
Index:
[0] = Trigger input I
[1] = D input D
[2] = Set S
[3] = Reset R
Description:
Display parameter for output Q of instance DFR 2 of the D flipflop.
Description:
Display parameter for the inverted output QN of instance DFR 2 of the D flipflop.
Description:
Setting parameter for the run-time group in which instance DFR 2 of the D flipflop is to be called.
Value:
1:
Run-time group 1
2:
Run-time group 2
3:
Run-time group 3
4:
Run-time group 4
5:
Run-time group 5
6:
Run-time group 6
9999: Do not calculate
Description:
Setting parameter for the run-time group of instance DFR 2 within the run-time group set in p20332.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
p20328
RSR 2 run sequence / RSR 2 RunSeq
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
T
Scaling:
-
Data set:
-
Min Max Factory
setting
0 7999
850
p20329[0...3]
BI: DFR 2 inputs / DFR 2 inputs
Access level:
3
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Data set:
-
Min Max Factory
setting
- - 0
r20330
BO: DFR 2 output Q / DFR 2 output Q
Access level:
3
Calculated:
-
Data type:
Unsigned32
Unit:
-
Scaling:
-
Data set:
-
r20331
BO: DFR 2 inverted output QN / DFR 2 inv outp QN
Access level:
3
Calculated:
-
Data type:
Unsigned32
Unit:
-
Scaling:
-
Data set:
-
p20332
DFR 2 run-time group / DFR 2 RTG
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
T
Scaling:
-
Data set:
-
Min Max Factory
setting
1 9999
9999
p20333
DFR 2 run sequence / DFR 2 RunSeq
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
T
Scaling:
-
Data set:
-
Min Max Factory
setting
0 32000
870
Содержание CU230P-2 CAN
Страница 1: ...s SINAMICS G120 Control Units CU230P 2 Parameter Manual 11 2009 SINAMICS ...
Страница 2: ......
Страница 666: ...Index C 666 Siemens AG 2009 All Rights Reserved SINAMICS G120 Control Units CU230P 2 Parameter Manual LH9 11 2009 ...
Страница 667: ......