List of Parameters
Parameters
1-253
© Siemens AG 2009 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009
Description:
Trigger signal for the selected faults and alarms
Dependency:
If one of the faults or alarms selected in p2128[n] occurs, then the particular bit of this binector output is set.
Refer to: p2128
Note:
CO: r2129 = 0 --> None of the selected messages has occurred.
CO: r2129 > 0 --> At least one of the selected messages has occurred.
Description:
Displays the system runtime in days when the fault occurred.
Dependency:
Refer to: r0945, r0947, r0948, r0949, r2109, r2133, r2136, p8401
Notice:
The time comprises r2130 (days) and r0948 (milliseconds).
The value displayed in p2130 refers to 01.01.1970.
Note:
The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
Description:
Displays the code of the oldest active fault.
Note:
0: No fault present.
Description:
Displays the code of the last alarm that occurred.
Note:
0: No alarm present.
Description:
Displays additional information about the fault that occurred for float values.
Dependency:
Refer to: r0945, r0947, r0948, r0949, r2109, r2130, r2136
Note:
The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
r2129.0...15
CO/BO: Trigger word for faults and alarms / Trigger word
Access level:
3
Calculated:
-
Data type:
Unsigned16
Unit:
-
Scaling:
-
Data set:
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Trigger signal p2128[0]
On
Off
-
01
Trigger signal p2128[1]
On
Off
-
02
Trigger signal p2128[2]
On
Off
-
03
Trigger signal p2128[3]
On
Off
-
04
Trigger signal p2128[4]
On
Off
-
05
Trigger signal p2128[5]
On
Off
-
06
Trigger signal p2128[6]
On
Off
-
07
Trigger signal p2128[7]
On
Off
-
08
Trigger signal p2128[8]
On
Off
-
09
Trigger signal p2128[9]
On
Off
-
10
Trigger signal p2128[10]
On
Off
-
11
Trigger signal p2128[11]
On
Off
-
12
Trigger signal p2128[12]
On
Off
-
13
Trigger signal p2128[13]
On
Off
-
14
Trigger signal p2128[14]
On
Off
-
15
Trigger signal p2128[15]
On
Off
-
r2130[0...63]
Fault time received in days / t_fault recv days
Access level:
3
Calculated:
-
Data type:
Unsigned16
Unit:
-
Scaling:
-
Data set:
-
r2131
CO: Actual fault code / Actual fault code
Access level:
2
Calculated:
-
Data type:
Unsigned16
Unit:
-
Scaling:
-
Data set:
-
r2132
CO: Actual alarm code / Actual alarm code
Access level:
2
Calculated:
-
Data type:
Unsigned16
Unit:
-
Scaling:
-
Data set:
-
r2133[0...63]
Fault value for float values / Fault val float
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Unit:
-
Scaling:
-
Data set:
-