Parameters
List of Parameters
1-368
© Siemens AG 2009 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009
Description:
Setting parameter for pulse duration T in milliseconds of instance MFP 1 of the pulse generator.
Description:
Display parameter for output pulse Q of instance MFP 1 of the pulse generator.
Description:
Setting parameter for the run-time group in which the instance MFP 1 of the pulse generator is to be called.
Value:
5:
Run-time group 5
6:
Run-time group 6
9999: Do not calculate
Description:
Setting parameter for the run sequence of instance MFP 1 within the run-time group set in p20146.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description:
Sets the signal source for the input pulse I of instance PCL 0 of the pulse shortener.
Description:
Setting parameter for pulse duration T in milliseconds of instance PCL 0 of the pulse shortener.
Description:
Display parameter for output pulse Q of instance PCL 0 of the pulse shortener.
p20144
MFP 1 pulse duration in ms / MFP 1 pulse_dur ms
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
T
Scaling:
-
Data set:
-
Min Max Factory
setting
0.00 60000.00
0.00
r20145
BO: MFP 1 output Q / MFP 1 output Q
Access level:
3
Calculated:
-
Data type:
Unsigned32
Unit:
-
Scaling:
-
Data set:
-
p20146
MFP 1 run-time group / MFP 1 RTG
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
T
Scaling:
-
Data set:
-
Min Max Factory
setting
5 9999
9999
p20147
MFP 1 run sequence / MFP 1 RunSeq
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
T
Scaling:
-
Data set:
-
Min Max Factory
setting
0 32000
380
p20148
BI: PCL 0 input pulse I / PCL 0 inp_pulse I
Access level:
3
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Data set:
-
Min Max Factory
setting
- - 0
p20149
PCL 0 pulse duration in ms / PCL 0 pulse_dur ms
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
T
Scaling:
-
Data set:
-
Min Max Factory
setting
0.00 60000.00
0.00
r20150
BO: PCL 0 output Q / PCL 0 output Q
Access level:
3
Calculated:
-
Data type:
Unsigned32
Unit:
-
Scaling:
-
Data set:
-