Description:
Binector output for bit-serial interconnection of PZD1 (normally control word 1) received from the PROFIBUS mas-
ter.
Description:
Binector output for bit-serial interconnection of PZD2 received from the PROFIBUS master.
r2090.0...15
BO: PROFIdrive PZD1 receive bit-serial / PZD1 recv bitw
Access level:
3
Calculated:
-
Data type:
Unsigned16
Unit:
-
Scaling:
-
Data set:
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Bit 0
On
Off
-
01
Bit 1
On
Off
-
02
Bit 2
On
Off
-
03
Bit 3
On
Off
-
04
Bit 4
On
Off
-
05
Bit 5
On
Off
-
06
Bit 6
On
Off
-
07
Bit 7
On
Off
-
08
Bit 8
On
Off
-
09
Bit 9
On
Off
-
10
Bit 10
On
Off
-
11
Bit 11
On
Off
-
12
Bit 12
On
Off
-
13
Bit 13
On
Off
-
14
Bit 14
On
Off
-
15
Bit 15
On
Off
-
r2091.0...15
BO: PROFIdrive PZD2 receive bit-serial / PZD2 recv bitw
Access level:
3
Calculated:
-
Data type:
Unsigned16
Unit:
-
Scaling:
-
Data set:
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Bit 0
On
Off
-
01
Bit 1
On
Off
-
02
Bit 2
On
Off
-
03
Bit 3
On
Off
-
04
Bit 4
On
Off
-
05
Bit 5
On
Off
-
06
Bit 6
On
Off
-
07
Bit 7
On
Off
-
08
Bit 8
On
Off
-
09
Bit 9
On
Off
-
10
Bit 10
On
Off
-
11
Bit 11
On
Off
-
12
Bit 12
On
Off
-
13
Bit 13
On
Off
-
14
Bit 14
On
Off
-
15
Bit 15
On
Off
-
Содержание CU230P-2 CAN