List of Parameters
Parameters
1-91
© Siemens AG 2009 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009
Description:
Displays the actual value at the digital inputs.
This means that the actual input signal can be checked at terminal DI x prior to switching from the simulation mode
(p0795.x = 1) to the terminal mode (p0795.x = 0). The input signal at terminal DI x is displayed in bit x of r0721.
Note:
DI: Digital input
AI: Analog Input
T: Terminal
Description:
Displays the status of the digital inputs.
Dependency:
Refer to: r0723
Note:
DI: Digital input
AI: Analog Input
T: Terminal
Description:
Displays the inverted status of the digital inputs.
Dependency:
Refer to: r0722
Note:
DI: Digital input
AI: Analog Input
T: Terminal
r0721
CU digital inputs, terminal actual value / CU DI actual value
Access level:
2
Calculated:
-
Data type:
Unsigned32
Unit:
-
Scaling:
-
Data set:
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
DI 0 (T. 5)
High
Low
-
01
DI 1 (T. 6)
High
Low
-
02
DI 2 (T. 7)
High
Low
-
03
DI 3 (T. 8)
High
Low
-
04
DI 4 (T. 16)
High
Low
-
05
DI 5 (T. 17)
High
Low
-
11
DI 11 (T. 3, 4) AI 0
High
Low
-
12
DI 12 (T. 10, 11) AI 1
High
Low
-
r0722.0...12
CO/BO: CU digital inputs, status / CU DI status
Access level:
2
Calculated:
-
Data type:
Unsigned32
Unit:
-
Scaling:
-
Data set:
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
DI 0 (T. 5)
High
Low
-
01
DI 1 (T. 6)
High
Low
-
02
DI 2 (T. 7)
High
Low
-
03
DI 3 (T. 8)
High
Low
-
04
DI 4 (T. 16)
High
Low
-
05
DI 5 (T. 17)
High
Low
-
11
DI 11 (T. 3, 4) AI 0
High
Low
-
12
DI 12 (T. 10, 11) AI 1
High
Low
-
r0723.0...12
CO/BO: CU digital inputs, status inverted / CU DI status inv
Access level:
3
Calculated:
-
Data type:
Unsigned32
Unit:
-
Scaling:
-
Data set:
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
DI 0 (T. 5)
High
Low
-
01
DI 1 (T. 6)
High
Low
-
02
DI 2 (T. 7)
High
Low
-
03
DI 3 (T. 8)
High
Low
-
04
DI 4 (T. 16)
High
Low
-
05
DI 5 (T. 17)
High
Low
-
11
DI 11 (T. 3, 4) AI 0
High
Low
-
12
DI 12 (T. 10, 11) AI 1
High
Low
-
Содержание CU230P-2 CAN
Страница 1: ...s SINAMICS G120 Control Units CU230P 2 Parameter Manual 11 2009 SINAMICS ...
Страница 2: ......
Страница 666: ...Index C 666 Siemens AG 2009 All Rights Reserved SINAMICS G120 Control Units CU230P 2 Parameter Manual LH9 11 2009 ...
Страница 667: ......