Displays the determined moment of inertia of the drive.
After it has been determined, the value is transferred to p0341, p0342.
Dependency:
IEC drives (p0100 = 0): unit kg m^2
NEMA drives (p0100 = 1): unit lb ft^2
Refer to: p0341, p0342, p1959
Refer to: F07984
Description:
Displays the vibration frequencies determined by the vibration test.
Index:
[0] = Frequency low
[1] = Frequency high
Dependency:
Refer to: p1959
Refer to: F07985
Description:
Sets the pole position identification technique.
Value:
1:
Voltage pulsing, first harmonic
4:
Voltage pulsing, 2-stage
6:
Voltage pulsing, 2-stage invert
10:
DC current injection
Dependency:
Refer to: p1780
Note:
Voltage pulse technique (p1980 = 1, 4) cannot be applied to operation with sine-wave output filters (p0230).
Description:
Displays the angular difference between the actual electrical commutation angle and the angle determined by the
pole position identification.
Dependency:
Refer to: p0325, p0329, p1980, r1985, r1987
Note:
When the pole position identification routine is executed several times, the spread of the measured values can be
determined using this value. At the same position, the spread should be less than 2 degrees electrical.
Description:
Displays the saturation characteristic of the pole position identification routine.
The values for the characteristic of the last saturation-based pole position identification routine are output every 1
ms in order to record signals (e.g. trace).
Dependency:
Refer to: p0325, p0329, p1980, r1984, r1987
r1969
Speed_ctrl_opt moment of inertia determined / n_opt M_inert det
Access level:
4
Calculated:
-
Data type:
FloatingPoint32
Unit:
[kgm²]
Scaling:
-
Data set:
-
r1970[0...1]
Speed_ctrl_opt vibration test vibration frequency determined / n_opt f_vibration
Access level:
4
Calculated:
-
Data type:
FloatingPoint32
Unit:
[Hz]
Scaling:
-
Data set:
-
p1980[0...n]
Pole position identification technique / PolID technique
Access level:
4
Calculated:
-
Data type:
Integer16
Can be changed:
U, T
Scaling:
-
Data set:
MDS
Min Max Factory
setting
1 10
4
r1984
Pole position identification, angular difference / PolID ang diff
Access level:
4
Calculated:
-
Data type:
FloatingPoint32
Unit:
[°]
Scaling:
-
Data set:
-
r1985
Pole position identification, saturation characteristic / PolID sat_char
Access level:
4
Calculated:
-
Data type:
FloatingPoint32
Unit:
[Arms]
Scaling:
-
Data set:
-