List of Parameters
Parameters
1-399
© Siemens AG 2009 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009
Description:
Setting parameter for the run sequence of instance PDE 2 within the run-time group set in p20347.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description:
Sets the signal source for the input pulse I of instance PDF 3 of the breaking delay device.
Description:
Setting parameter for pulse extension time T in milliseconds of instance PDF 3 of the breaking delay device.
Description:
Display parameter for output pulse Q of instance PDF 3 of the breaking delay device.
Description:
Setting parameter for the run-time group in which the instance PDF 3 of the breaking delay device is to be called.
Value:
5:
Run-time group 5
6:
Run-time group 6
9999: Do not calculate
Description:
Setting parameter for the run sequence of instance PDE 3 within the run-time group set in p20352.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description:
Sets the signal source for the input pulse I of instance MFP 2 of the pulse generator.
p20348
PDF 2 run sequence / PDF 2 RunSeq
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
T
Scaling:
-
Data set:
-
Min Max Factory
setting
0 32000
920
p20349
BI: PDF 3 input pulse I / PDF 3 inp_pulse I
Access level:
3
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Data set:
-
Min Max Factory
setting
- - 0
p20350
PDF 3 pulse extension time in ms / PDF 3 t_ext ms
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
T
Scaling:
-
Data set:
-
Min Max Factory
setting
0.00 60000.00
0.00
r20351
BO: PDF 3 output Q / PDF 3 output Q
Access level:
3
Calculated:
-
Data type:
Unsigned32
Unit:
-
Scaling:
-
Data set:
-
p20352
PDF 3 run-time group / PDF 3 RTG
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
T
Scaling:
-
Data set:
-
Min Max Factory
setting
5 9999
9999
p20353
PDF 3 run sequence / PDF 3 RunSeq
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
T
Scaling:
-
Data set:
-
Min Max Factory
setting
0 32000
930
p20354
BI: MFP 2 input pulse I / MFP 2 inp_pulse I
Access level:
3
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Data set:
-
Min Max Factory
setting
- - 0
Содержание CU230P-2 CAN