Parameters
List of Parameters
1-332
© Siemens AG 2009 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009
Description:
Displays the parameters that were not able to be transferred when reading the parameter back-up files (PS files)
from the non-volatile memory (e.g. memory card).
r9406[0] = 0
--> All of the parameter values were able to be transferred error-free.
r9406[0...x] > 0
--> Displays the parameter number whose value was not able to be completely transferred or for an indexed param-
eter, for at least 1 index, was not able to be transferred. The first index that is not transferred is displayed in r9407.
Dependency:
Refer to: r9407, r9408
Note:
All indices from r9406 to r9408 designate the same parameter.
r9406[x] parameter number, parameter not accepted
r9407[x] parameter index, parameter not accepted
r9408[x] fault code, parameter not accepted
Description:
Displays the first index of the parameters that could not be transferred when the parameter backup files (PS files)
were read from the non-volatile memory (e.g. memory card).
If, from an indexed parameter, at least one index was not able to be transferred, then the parameter number is dis-
played in r9406[n] and the first index that was not transferred is displayed in r9407[n].
r9406[0] = 0
--> All of the parameter values were able to be transferred error-free.
r9406[n] > 0
--> Displays r9407[n] the first index of the parameter number r9406[n] that was not transferred.
Dependency:
Refer to: r9406, r9408
Note:
All indices from r9406 to r9408 designate the same parameter.
r9406[x] parameter number, parameter not accepted
r9407[x] parameter index, parameter not accepted
r9408[x] fault code, parameter not accepted
Description:
Only for internal Siemens service purposes.
Dependency:
Refer to: r9406, r9407
Note:
All indices from r9406 to r9408 designate the same parameter.
r9406[x] parameter number, parameter not accepted
r9407[x] parameter index, parameter not accepted
r9408[x] fault code, parameter not accepted
Description:
Displays the number of modified parameters and those that have still not be saved for this drive object.
Dependency:
Refer to: p0971
Note:
The modified parameters that still need to be saved are internally listed in r9410 ... r9419.
r9406[0...19]
PS file parameter number parameter not transferred / PS parameter No.
Access level:
4
Calculated:
-
Data type:
Unsigned16
Unit:
-
Scaling:
-
Data set:
-
r9407[0...19]
PS file parameter index parameter not transferred / PS parameter index
Access level:
4
Calculated:
-
Data type:
Unsigned16
Unit:
-
Scaling:
-
Data set:
-
r9408[0...19]
PS file fault code parameter not transferred / PS fault code
Access level:
4
Calculated:
-
Data type:
Unsigned16
Unit:
-
Scaling:
-
Data set:
-
r9409
Number of parameters to be saved / Qty par to save
Access level:
4
Calculated:
-
Data type:
Unsigned16
Unit:
-
Scaling:
-
Data set:
-