Parameters
List of Parameters
1-24
© Siemens AG 2009 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009
Bit 19 = 1 (internal pulse enable missing), if:
- sequence control does not have a finished message.
Bit 20 = 1 (internal DC brake active), if:
- the drive is not in the state "Operation" or in "OFF1/3".
- the internal pulse enable is missing (r0046.19 = 0).
Bit 21 = 1 (enable signal missing), if:
- the power unit does not issue an enable signal (e.g. because DC link voltage is too low).
- hibernation is active.
Bit 25 = 1 (function bypass active) if:
- the bypass function is active.
Bit 26 = 1 (enable signal missing), if:
- the drive is not operational.
Bit 27 = 1 (enable signal missing), if:
- demagnetization not completed.
Bit 30 = 1 (speed controller inhibited), if one of the following reasons is present:
- the pole position identification is active.
- motor data identification is active (only certain steps).
Bit 31 = 1 (enable signal missing), if:
- the speed setpoint from jog 1 or 2 is entered.
Description:
Displays the actual status for the motor data identification (standstill measurement) and the speed/velocity control-
ler optimization (rotating measurement).
Value:
0:
No measurement
115:
Measurement q leakage inductance (part 2)
120:
Speed controller optimization (vibration test)
140:
Calculate speed controller setting
150:
Measurement, moment of inertia
170:
Measurement, magnetizing current and saturation characteristic
195:
Measurement q leakage inductance (part 1)
200:
Rotating measurement selected
220:
identification, leakage inductance
230:
Identification, rotor time constant
240:
Identification, stator inductance
250:
Identification, stator inductance LQLD
270:
Identification, stator resistance
290:
Identification, valve lockout time
300:
Standstill measurement selected
Note:
r0047 = 300 is also displayed if encoder calibration p1990 is selected.
Description:
Displays the effective Command Data Set (CDS).
Dependency:
Refer to: p0810, p0811, r0836
Note:
The Command Data Set selected using a binector input (e.g. p0810) is displayed using r0836.
r0047
Motor data ident. routine and speed controller optimization / MotID and n_opt
Access level:
1
Calculated:
-
Data type:
Integer16
Unit:
-
Scaling:
-
Data set:
-
r0050.0...1
CO/BO: Command Data Set CDS effective / CDS effective
Access level:
3
Calculated:
-
Data type:
Unsigned8
Unit:
-
Scaling:
-
Data set:
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
CDS eff., bit 0
On
Off
-
01
CDS eff., bit 1
On
Off
-