Description:
Displays all of the devices connected to the CAN bus after run-up.
r8600
= 00000000 hex: No drive recognized.
= 02010192 hex: 1 Vector drive
Note:
Corresponds to the CANopen object 1000 hex.
For each detected drive, the device type is displayed in object 67FF hex.
Description:
Displays the error register for CANopen.
Bit 0: Generic error
0 signal: No error present.
1 signal: Generic error present.
Bit 1 ... 3: Not supported (always a 0 signal)
Bit 4: Communications error
0 signal: There is no message in the range 8700 ... 8799.
1 signal: There is at least one message (fault or alarm) in the range 8700 ... 8799.
Bit 5 ... 6: Not supported (always a 0 signal)
Bit 7:; Fault outside the range 8700 ... 8799
0 signal: There is no fault outside the range 8700 ... 8799.
1 signal: There is at least one fault outside the range 8700 ... 8799.
Note:
Corresponds to the CANopen object 1001 hex.
Description:
Sets the SYNC object parameter for the following CANopen objects:
- 1005 hex: COB-ID
Note:
SINAMICS operates as SYNC load.
COB-ID: CAN object identification
Description:
Sets the COB ID of the emergency message (error telegram). It corresponds to the CANopen objects:
- 1014 hex: COB-ID
Note:
If, when downloading, the preset value 0 is downloaded, then the CANopen preset value 80 hex + Node-ID is auto-
matically set.
Online, the value 0 is rejected as, according to the CANopen Standard, COB ID 0 is not permitted here.
The changeover of the node ID using the hardware switch at the CU or per software has no effect on the COB-ID
EMCY. The saved value remains effective.
r8600
CAN device type / Device type
CU230P-2 CAN
Access level:
3
Calculated:
-
Data type:
Unsigned32
Unit:
-
Scaling:
-
Data set:
-
r8601
CAN error register / Error register
CU230P-2 CAN
Access level:
3
Calculated:
-
Data type:
Unsigned8
Unit:
-
Scaling:
-
Data set:
-
p8602
CAN SYNC object / SYNC object
CU230P-2 CAN
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
C(1), T
Scaling:
-
Data set:
-
Min Max Factory
setting
0000 hex
FFFF FFFF hex
0080 hex
p8603
CAN COB ID Emergency Message / COB ID EMCY Msg
CU230P-2 CAN
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
C(1), T
Scaling:
-
Data set:
-
Min Max Factory
setting
0000 hex
FFFF FFFF hex