List of Parameters
Parameters
1-369
© Siemens AG 2009 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009
Description:
Setting parameter for the run-time group in which the instance PCL 0 of the pulse shortener is to be called.
Value:
5:
Run-time group 5
6:
Run-time group 6
9999: Do not calculate
Description:
Setting parameter for the run sequence of instance PCL 0 within the run-time group set in p20151.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description:
Sets the signal source for the input pulse I of instance PCL 1 of the pulse shortener.
Description:
Setting parameter for pulse duration T in milliseconds of instance PCL 1 of the pulse shortener.
Description:
Display parameter for output pulse Q of instance PCL 1 of the pulse shortener.
Description:
Setting parameter for the run-time group in which the instance PCL 1 of the pulse shortener is to be called.
Value:
5:
Run-time group 5
6:
Run-time group 6
9999: Do not calculate
p20151
PCL 0 run-time group / PCL 0 RTG
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
T
Scaling:
-
Data set:
-
Min Max Factory
setting
5 9999
9999
p20152
PCL 0 run sequence / PCL 0 RunSeq
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
T
Scaling:
-
Data set:
-
Min Max Factory
setting
0 32000
400
p20153
BI: PCL 1 input pulse I / PCL 1 inp_pulse I
Access level:
3
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Data set:
-
Min Max Factory
setting
- - 0
p20154
PCL 1 pulse duration in ms / PCL 1 pulse_dur ms
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
T
Scaling:
-
Data set:
-
Min Max Factory
setting
0.00 60000.00
0.00
r20155
BO: PCL 1 output Q / PCL 1 output Q
Access level:
3
Calculated:
-
Data type:
Unsigned32
Unit:
-
Scaling:
-
Data set:
-
p20156
PCL 1 run-time group / PCL 1 RTG
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
T
Scaling:
-
Data set:
-
Min Max Factory
setting
5 9999
9999