List of Parameters
Parameters
1-299
© Siemens AG 2009 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009
Description:
Successfully completed component of the last rotating measurement carried out.
Dependency:
Refer to: r3925
Note:
The parameter is a copy of p1959.
Description:
Configuration of voltage generation for the various MotID sections in the case of the most recent successful MotID.
Description:
Displays the characteristics (A5E number and versions) of the power unit.
[0]: A5E number xxxx (A5Exxxxyyyy)
[1]: A5E number yyyy (A5Exxxxyyyy)
[2]: File version (logistic)
[3]: File version (fixed data)
[4]: File version (calib data)
Description:
For service personnel only.
r3928[0...n]
Rotating measurement configuration / Rot meas config
Access level:
3
Calculated:
p0340 = 1
Data type:
Unsigned16
Unit:
-
Scaling:
-
Data set:
DDS, p0180
Bit field:
Bit
Signal name
1 signal
0 signal
FP
01
Saturation characteristic identification
Yes
No
-
02
Moment of inertia identification
Yes
No
-
03
Recalculates the speed controller parame-
ters
Yes
No
-
04
Speed controller optimization (vibration test) Yes
No
-
05
q-leakage inductance ident. (for current
controller adaptation)
Yes
No
-
r3929[0...n]
Motor data identification alternating voltage generation / MotID alt. voltgen
Access level:
4
Calculated:
p0340 = 1
Data type:
Unsigned32
Unit:
-
Scaling:
-
Data set:
DDS, p0180
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Alternating voltage generation for determ.
dead-time correction
Yes
No
-
01
Alternating voltage generation for determ. of
stator resistance
Yes
no
-
02
Alternating voltage generation for determ.
rotor time constant
Yes
no
-
03
Alternating voltage generation for determ.
leakage inductance
Yes
no
-
04
Alternat. voltage generation for determ. dyn.
leakage inductance
Yes
no
-
05
Alternat. voltage generation for determ.
magnetizing inductance
Yes
no
-
r3930[0...4]
Power unit EEPROM characteristics / PU characteristics
Access level:
3
Calculated:
-
Data type:
Unsigned16
Unit:
-
Scaling:
-
Data set:
-
p3950
Service parameter / Serv. par.
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
C, U, T
Scaling:
-
Data set:
-
Min Max Factory
setting
- - -
Содержание CU230P-2 CAN