Parameters
List of Parameters
1-294
© Siemens AG 2009 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009
Description:
Permissible speed deviation of the load monitoring (for p2193 = 2).
Dependency:
Refer to: r2169, p2181, p2193, p3230
Refer to: A07920, A07921, A07922, F07923, F07924, F07925
Description:
Sets the signal source for detecting a failure.
Dependency:
Refer to: p2192, p2193
Refer to: F07936
Note:
Monitoring is triggered when the input signal is zero, as soon as the time in p2192 has expired.
Description:
Sets the time constant of the PT1 element to smooth the torque actual value.
The smoothed actual torque is compared with the threshold values and is only used for messages and signals.
Description:
Sets the monitoring time for phase failure detection of the motor.
Notice:
After the value has been modified, no further parameter modifications can be made and the status is shown in
r3996. Modifications can be made again when r3996 = 0.
Note:
The function can be switched out with p3235 = 0.
The monitoring is automatically deactivated during the flying restart operation for a motor that is still rotating.
3-phase phase failures cannot be detected and are indicated by other error messages (e.g. F7902).
p3231[0...n]
Load monitoring speed deviation / Load monit n_dev
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Data set:
DDS, p0180
Min Max Factory
setting
0.00 [rpm]
210000.00 [rpm]
150.00 [rpm]
p3232[0...n]
BI: Load monitoring failure detection / Load_moni fail_det
Access level:
3
Calculated:
-
Data type:
U32 / Binary
Can be changed:
U, T
Scaling:
-
Data set:
CDS, p0170
Min Max Factory
setting
- - 1
p3233[0...n]
Torque actual value filter, time constant / M_act_filt T
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Data set:
DDS, p0180
Min Max Factory
setting
0 [ms]
1000000 [ms]
100 [ms]
p3235
Phase failure signal motor monitoring time / Ph_fail t_monit
Access level:
4
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Data set:
-
Min Max Factory
setting
0 [ms]
2000 [ms]
320 [ms]