301
1 – Fixe
d
F
requ
encie
s, dire
ct sele
ctio
n
- 3011 -
Function diagram
8
7
6
5
4
3
2
1
FP_3011_97_51.vsd
Setpoint channel
G120 CU230P-2
29.10.2009
V4.3
Fixed Frequencies, direct selection (p1016 = 1)
+
+
+
0 0 0 1
0 0 1 0
1 0 0 0
0 1 0 0
+
+
+
n_set_fixed 1
-210000.000 ... 210000.000 [1/min]
p1001 [D] (0.000)
r1024
n_set_fixed eff [1/min]
f_fixed status
r1025
[2505.2]
p1020
[2505.2]
p1021
[2505.2]
p1022
[2505.2]
p1023
STW setpoint chan
r1198
r1198
.0
STW setpoint chan
r1198
r1198
.1
STW setpoint chan
r1198
r1198
.2
STW setpoint chan
r1198
r1198
.3
n_set_fixed 2
-210000.000 ... 210000.000 [1/min]
p1002 [D] (0.000)
n_set_fixed 3
-210000.000 ... 210000.000 [1/min]
p1003 [D] (0.000)
n_set_fixed 4
-210000.000 ... 210000.000 [1/min]
p1004 [D] (0.000)