Parameters
List of Parameters
1-382
© Siemens AG 2009 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009
Description:
Sets the signal source of input quantity X of instance LIM 0 of the limiter.
Description:
Setting parameter for the upper limit value LU of instance LIM 0 of the limiter.
Description:
Setting parameter for the lower limit value LL of instance LIM 0 of the limiter.
Description:
Display parameter for the limited output quantity Y of instance LIM 0 of the limiter.
Description:
Display parameter of instance LIM 0 of limiter QU (upper limit reached), i.e. QU = 1 for X >= LU.
Description:
Display parameter of instance LIM 0 of limiter QL (lower limit reached), i.e. QL = 1 for X <= LL.
Description:
Setting parameter for the run-time group in which instance LIM 0 of the limiter is to be called.
Value:
5:
Run-time group 5
6:
Run-time group 6
9999: Do not calculate
p20228
CI: LIM 0 input X / LIM 0 input X
Access level:
3
Calculated:
-
Data type:
U32 / FloatingPoint32
Can be changed:
T
Scaling:
PERCENT
Data set:
-
Min Max Factory
setting
- - 0
p20229
LIM 0 upper limit value LU / LIM 0 upper lim LU
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
T
Scaling:
-
Data set:
-
Min Max Factory
setting
-340.28235E36 340.28235E36 0.0000
p20230
LIM 0 lower limit value LL / LIM 0 lower lim LL
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
T
Scaling:
-
Data set:
-
Min Max Factory
setting
-340.28235E36 340.28235E36 0.0000
r20231
CO: LIM 0 output Y / LIM 0 output Y
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Unit:
-
Scaling:
PERCENT
Data set:
-
r20232
BO: LIM 0 input quantity at the upper limit QU / LIM 0 QU
Access level:
3
Calculated:
-
Data type:
Unsigned32
Unit:
-
Scaling:
-
Data set:
-
r20233
BO: LIM 0 input quantity at the lower limit QL / LIM 0 QL
Access level:
3
Calculated:
-
Data type:
Unsigned32
Unit:
-
Scaling:
-
Data set:
-
p20234
LIM 0 run-time group / LIM 0 RTG
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
T
Scaling:
-
Data set:
-
Min Max Factory
setting
5 9999
9999