List of Parameters
Parameters
1-387
© Siemens AG 2009 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009
Description:
Sets the signal source for the "accept setting value" signal of instant INT 0 of the integrator.
Description:
Display parameter for output quantity Y of instance INT 0 of the integrator.
If LL>= LU, then the output quantity Y = LU.
Description:
Display parameter for the signal QU that output quantity Y of instance INT 0 of the integrator has reached the upper
limit value LU.
Description:
Display parameter for the signal QL that output quantity Y of instance INT 0 of the integrator has reached the lower
limit value LL.
Description:
Setting parameter for the run-time group in which instance INT 0 of the integrator is to be called.
Value:
5:
Run-time group 5
6:
Run-time group 6
9999: Do not calculate
Description:
Setting parameter for the run sequence of instance INT 0 within the run-time group set in p20264.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description:
Sets the signal source of input quantity X of instance LVM 0 of the double-sided limiter.
p20260
BI: INT 0 accept setting value S / INT 0 acc set val
Access level:
3
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Data set:
-
Min Max Factory
setting
- - 0
r20261
CO: INT 0 output Y / INT 0 output Y
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Unit:
-
Scaling:
PERCENT
Data set:
-
r20262
BO: INT 0 integrator at the upper limit QU / INT 0 QU
Access level:
3
Calculated:
-
Data type:
Unsigned32
Unit:
-
Scaling:
-
Data set:
-
r20263
BO: INT 0 integrator at the lower limit QL / INT 0 QL
Access level:
3
Calculated:
-
Data type:
Unsigned32
Unit:
-
Scaling:
-
Data set:
-
p20264
INT 0 run-time group / INT 0 RTG
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
T
Scaling:
-
Data set:
-
Min Max Factory
setting
5 9999
9999
p20265
INT 0 run sequence / INT 0 RunSeq
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
T
Scaling:
-
Data set:
-
Min Max Factory
setting
0 32000
700
p20266
CI: LVM 0 input X / LVM 0 input X
Access level:
3
Calculated:
-
Data type:
U32 / FloatingPoint32
Can be changed:
T
Scaling:
PERCENT
Data set:
-
Min Max Factory
setting
- - 0