Parameters
List of Parameters
1-68
© Siemens AG 2009 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009
Description:
Displays the ambient temperature of the motor temperature model.
Description:
Displays the stator core temperature of the motor temperature model.
Description:
Displays the stator winding temperature of the motor temperature model.
Description:
Displays the rotor temperature of the motor temperature model.
Description:
The non-linear and cross-coupled quadrature axis flux functions are defined using 4 coefficients.
The parameter weights the unsaturated component of the quadrature axis flux function.
Description:
The non-linear and cross-coupled quadrature axis flux functions are defined using 4 coefficients.
This parameter describes the interdependency of the unsaturated component of the quadrature axis current.
Dependency:
Refer to: p0634
Description:
The non-linear and cross-coupled quadrature axis flux functions are defined using 4 coefficients.
This parameter describes the interdependency of the unsaturated component of the direct axis current.
Dependency:
Refer to: p0634
r0630[0...n]
Motor temperature model ambient temperature / MotTMod T_amb.
Access level:
4
Calculated:
-
Data type:
FloatingPoint32
Unit:
[°C]
Scaling:
TEMP
Data set:
MDS
r0631[0...n]
Motor temperature model, stator core temperature / MotTMod T_core
Access level:
4
Calculated:
-
Data type:
FloatingPoint32
Unit:
[°C]
Scaling:
TEMP
Data set:
MDS
r0632[0...n]
Motor temperature model, stator winding temperature / MotTMod T_copper
Access level:
4
Calculated:
-
Data type:
FloatingPoint32
Unit:
[°C]
Scaling:
TEMP
Data set:
MDS
r0633[0...n]
Motor temperature model, rotor temperature / MotTMod T_rotor
Access level:
4
Calculated:
-
Data type:
FloatingPoint32
Unit:
[°C]
Scaling:
TEMP
Data set:
MDS
p0634[0...n]
Q flux flux constant unsaturated / PSIQ KPSI UNSAT
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
C(3), U, T
Scaling:
-
Data set:
MDS
Min Max Factory
setting
0.000 [Vsrms]
100.000 [Vsrms]
0.000 [Vsrms]
p0635[0...n]
Q flux quadrature axis current constant unsaturated / PSIQ KIQ UNSAT
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
C(3), U, T
Scaling:
-
Data set:
MDS
Min Max Factory
setting
0.00 [Arms]
10000.00 [Arms]
0.00 [Arms]
p0636[0...n]
Q flux direct axis current constant unsaturated / PSIQ KID UNSAT
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
C(3), U, T
Scaling:
-
Data set:
MDS
Min Max Factory
setting
0.00 [Arms]
10000.00 [Arms]
0.00 [Arms]