background image

REM3: Hand-held Two-way Remote Keypad
Reference and Installation Manual V1.10

PARADOX.COM
Printed in Canada - 05/2013
REM3-EI09

Overview

The REM3 combines the flexibility of a keypad with the convenience and mobility of a remote control. Its 15 buttons allow for a greater level of 
interaction with the system than regular remote controls, and the two-way transceiver allows for accurate feedback for up to two partitions.

Compatibility and Technical Specifications

The following table provides the compatibility and technical specifications for the REM3 Hand-held Two-way Remote Keypad.

MGSP Remote Control Programming

Use the following sections to program the various remote controls in your MGSP system.

Assigning the REM3 to the Panel

One-touch Arm Keys

The REM3 offers the use of one-touch arm keys. The use of one-touch arm keys must be enabled in section [703], options [1] to [3] in the panel.

PGM Key Assignment

The REM3 provides six PGM keys. See sections 

[610] 

to

 [642]

 in the panel to define the six PGM keys and two combo keys:

One-Touch Programming 

Program the REM3 to enable one-touch mode to disarm your system and/or trigger PGMs. By default, the REM3 is set to require code entry. 
Section 

[360]

 is used to configure all odd and even-numbered REM3s, while sections 

[361]

 to 

[376]

 are used to configure REM3s by pairs.

Specifications

RF frequency

433MHz or 868MHz

Battery type

One 3V lithium battery (2032)

Consumption

Standby: 0.9uA, 19mA during transmission

Battery life

Battery life expectancy is a minimum of 1 year.
“Low Battery Signal” is sent to the control panel when battery is below 2.2Vdc. Upon power-up, a “Low 
Battery Restore Signal” is sent to the control panel when the battery voltage level has reached 2.6Vdc 
or higher. The low battery restore feature is only compatible with the following:
MG series: 4.90 and up
SP series: 4.90 and up
SP65, SP4000: 5.10 and up
RTX3: V5.20 and up

Range 
(typical in a residential 
environment)

45m (150ft)

Compatibility

MG5000 / MG5050 V3.0 and higher / 
Spectra SP Series V3.0 and higher in conjunction with a RTX3 V1.31 and higher.
EVO V2.10 and higher in conjunction with a RTX3 V1.50 and higher.

IMPORTANT: 

The REM3 is not compatible with the RPT1 and will not benefit from the additional range.

Dimensions

8cm x 3.4cm x 1.5cm (3.1in x 1.3in x 0.6in)

Temperature Rage

0-50°C (32-120° F)

Humidity

5-90%

Weight

32 g (1.2 oz)

Standards

EN 50131-3 Grade 2 Class II 

(portable type B; certification body = Intertek)

Table 1: Steps for assigning the REM3 to an MGSP panel

 Step

 Fig. 1:Action on Keypad

Details

1

[

]  +  [

MASTER

 

CODE

]

The [ ] key will flash. 
LED/key on = programmed user.

[

PARTITION

 

MASTER

 

CODE

] may also be used.

2

[user number]

2 digits: 01 to 32

3

[code]

Enter 4- or 6-digit code

4

[confirm code]

Re-enter 4- or 6-digit code

5

[learn  remote] 

Press and hold the Information key ([i]) on the designated remote. 

Important: For partitioned 

systems, go to step 6. For non-partitioned systems, go to step 2 to add another remote or press [

CLEAR

] to 

exit. 

6

[1] and/or [2] + [

ENTER

]

Assign the user to one or both partitions, then press [

ENTER

]. 

Go to step 2 or press [

CLEAR

] to exit. 

Table 2: One-Touch arm key options

 Option Description

[703]

OFF

ON

1

One-touch regular arming

2

One-touch stay arming

3

One-touch sleep arming

Worksheet 1: Programming remote controls

REM3 Remote Control

PGM 1

[9]

PGM 2

[0]

PGM 3

[x]

PGM 4

[

]

PGM 5

[ ]

PGM 6

[ ]

PGM

[x] + [

]

PGM

[ ]  +  [ ]

Default Data

B

C

D

E

5

6

SLEEP

SLEEP

Section

Default

[610]

ALL RCs

_____

_____

_____

_____

_____

_____

_____

_____

Important: When section [610] is accessed, the panel will copy the saved value of that section to all remotes.

[611]

RC#1

_____

_____

_____

_____

_____

_____

_____

_____

_____

_____

_____

_____

_____

_____

_____

_____

[642]

RC# 32

_____

_____

_____

_____

_____

_____

_____

_____

Table 3: Programming One-touch

[360]

Odd-numbered REM3s

[1]

 PGM activate/deactivate

[2]

 Disarm

OFF 

=

 Code entry

OFF 

=

 Code entry

ON = One-touch
ON = One-touch

[3]

 & 

[4]

N/A

N/A

Even-numbered REM3s

[5] 

PGM activate/deactivate

[6] 

Disarm

OFF 

=

 Code entry

OFF 

=

 Code entry 

ON = One-touch
ON = One-touch

[361]

REM3 #1

[1] 

PGM activate/deactivate

[2] 

Disarm

OFF 

=

 Code entry

OFF 

=

 Code entry 

ON = One-touch
ON = One-touch 

[3]

 & 

[4]

N/A

N/A

REM3 #2

[5] 

PGM activate/deactivate

[6] 

Disarm

OFF 

=

 Code entry

OFF 

=

 Code entry 

ON = One-touch
ON = One-touch

[376]

REM3 #31

[1] 

PGM activate/deactivate

[2] 

Disarm

OFF 

=

 Code entry

OFF 

=

 Code entry 

ON = One-touch
ON = One-touch 

[3]

 & 

[4]

N/A

N/A

REM3 #32

[5] 

PGM activate/deactivate

[6] 

Disarm

OFF 

=

 Code entry

OFF 

=

 Code entry 

ON = One-touch
ON = One-touch

[

SLEEP

]

 - Empty / Button disabled

[1] 

-

 

Regular / Regular Force arming

[2] 

-

 

Stay / Stay Force arming

[3] 

- N/A

[4] 

- Sleep / Sleep Force arming

[5] 

-

 

PGM Activation (Event Group #22)

[6] 

- PGM Activation (Event Group #23)

[7] 

- N/A

[8] 

- Panic 1

[9] 

- Panic 2

[A] 

- Panic 3

[B] 

- PGM Activation (Event Group #8)

[C] 

- PGM Activation (Event Group #9)

[D] 

- PGM Activation (Event Group #10)

[E] 

- PGM Activation (Event Group #11)

[F] 

- Paramedic alarm

PGM Key Definitions Table