NetCol8000-C(070-260) In-room Chilled Water Smart
Cooling Product
User Manual
4 Commissioning
Issue 06 (2020-01-13)
Copyright © Huawei Technologies Co., Ltd.
158
Procedure
Step 1
Tap
Shutdown
on the home screen. A warning is displayed, indicating whether to shut down
the smart cooling product, as shown in
Figure 4-29
Shutdown
Step 2
Tap
Confirm
. If the device is successfully shut, the system displays a message, indicating that
the command is successfully triggered.
Step 3
Disconnect the general switch (For a device that has two power inputs, disconnect the active
power switch QF1 and standby power switch QF2).
Step 4
(Optional) If the smart cooling product needs to be maintained in power-off mode or
long-term power-off, switch off the smart cooling product circuit breaker on PDC.
If the NetCol8000-C will be idle for a long time, ensure that the circulation water inside the
system has a temperature no lower than 3°C , or has used antifreeze liquid, otherwise, the heat
exchanging pipes of the smart cooling product may freeze up and crack. If the water
temperature does not meet the requirement, drain all water out of the NetCol8000-C and
switch off the chilled water stop valve.
----End
4.8 Checking After Commissioning
lists the commissioning checklist.
Table 4-13
Commissioning checklist
Check Item
Actual Result
No oil stain exists on the copper pipe thermal insulation foam or
□ Passed □ Failed