![ABB ACS380 Series Скачать руководство пользователя страница 96](http://html.mh-extra.com/html/abb/acs380-series/acs380-series_firmware-manual_2560096.webp)
96 Program features
Tips
• You can connect Slow down and Stop signals into the same signal source by
setting the Stop limit and Slow down parameters to the same digital input (
76.01
Forward stop limit = DI2 and
76.05
Forward slow down limit = DI2).
• You can change the Limit to limit state machine state with the parameter Limit to
limit state parameter (
76.01
), in case of maintenance.
Settings
Parameter groups
21 Start/stop mode
(page
169
),
23 Speed reference ramp
(page
190
) and
28 Frequency reference chain
(page
203
).
Paramters
76.01
Limit to limit control status
(page
322
),
76.02
Enable limit to limit
control
(page
322
),
76.03
Limit to limit trigger type
(page
323
),
76.04
Forward stop
limit
(page
323
),
76.05
Forward slow down limit
(page
324
),
76.06
Reverse stop limit
(page
325
),
76.07
Reverse slow down limit
(page
325
),
76.08
Slow down speed
(page
325
) and
76.09
Slow down frequency
(page
325
).
ACS380 FW.book Page 96 Friday, May 4, 2018 4:18 PM