Parameters 231
31.33
Emergency ramp
supervision delay
If parameter
31.32
Emergency ramp supervision
is set to
0%, this parameter defines the maximum time an
emergency stop (mode Off1 or Off3) is allowed to take. If
the motor has not stopped when the time elapses, the
drive trips on
73B0
Emergency ramp failed
, sets bit 8 of
06.17
Drive status word 2
, and coasts to a stop.
If
31.32
is set to a value other than 0%, this parameter
defines a delay between the receipt of the emergency
stop command and the activation of the supervision. It is
recommended to specify a short delay to allow the speed
change rate to stabilize.
0 s
0…100 s
Maximum ramp-down time, or supervision activation
delay.
1 = 1 s
31.205 Crane warning
masking
Selects which crane warnings trigger events to the drive.
Whenever a bit of this parameter is set to 1, the
corresponding warning can trigger an event.
If a bit is set to 0, the warning does not appear in the event
logger or control panel, and the warning can be read only
from parameters
09.01
Crane SW1
.The bits of this binary
number correspond to the following warnings:
FFFFh
0000h...FFFFh
Crane warning masking status word
1 = 1
No.
Name/Value
Description
Default
FbEq 16
Bit
Name
Description
0
Brake slip at standstill
D200 Brake slip at standstill2
1
Slowdown forward/reverse D201 Forward slowdown limit, D202 Reverse slowdown limit
2
Reserved
3
Reserved
4
End limit forward/reverse D205 Forward stop limit,
D206 Reverse stop limit
5
Reserved
6
Joystick reference check
D208 Joystick reference check
7
Joystick zero position
D209 Joystick zero position2
8
Power on acknowledge
D20B Power on acknowledge
9
Reserved
10
Fast stop
D20A Fast stop
11…15 Reserved