![ABB ACS380 Series Скачать руководство пользователя страница 287](http://html.mh-extra.com/html/abb/acs380-series/acs380-series_firmware-manual_2560287.webp)
Parameters 287
45.14
Tariff selection
Selects (or defines a source that selects) which pre-
defined energy tariff is used.
0 =
45.12
Energy tariff 1
1 =
45.13
Energy tariff 2
Energy tariff
1
Energy tariff 1
0.
0
Energy tariff 2
1.
1
DI1
Digital input DI1 (
10.02
DI delayed status
, bit 0).
2
DI2
Digital input DI2 (
10.02
DI delayed status
, bit 1).
3
DI3
Digital input DI3 (
10.02
DI delayed status
, bit 2).
4
DI4
Digital input DI4 (
10.02
DI delayed status
, bit 3).
5
Other [bit]
Source selection (see
Terms and abbreviations
).
-
45.18
CO2 conversion factor
Defines a factor for conversion of saved energy into CO
2
emissions (kg/kWh or tn/MWh). For example,
45.10
Total saved CO2
=
45.02 Saved kW hours
×
45.18
CO2 conversion factor
(tn/MWh).
0.500
tn/MWh
0.000…65.535
tn/MWh
Factor for conversion of saved energy into CO
2
emissions.
1 = 1 tn/MWh
45.19
Comparison power
Actual power that the motor absorbs when connected
direct-on-line and operating the application. The value is
used for reference when energy savings are calculated.
Note:
The accuracy of the energy savings calculation is
directly dependent on the accuracy of this value. If nothing
is entered here, then the nominal motor power is used by
the calculation, but that may inflate the energy savings
reported as many motors do not absorb nameplate power.
0.00 kW
0.00…100000.00 kW
Motor power.
1 = 1 kW
45.21
Energy calculations
reset
Resets the savings counter parameters
45.01
…
45.10
.
Done
Done
Reset not requested (normal operation), or reset
complete.
0
Reset
Reset the savings counter parameters. The value reverts
automatically to
Done
.
1
45.24
Hourly peak power
value
Value of the peak power during the last hour, that is, the
most recent 60 minutes after the drive has been powered
up.
The parameter is updated once every 10 minutes unless
the hourly peak is found in the most recent 10 minutes. In
that case, the values is shown immediately.
0.00 kW
-3000.00 … 3000.00
kW
Peak power value.
10 = 1 kW
45.25
Hourly peak power
time
Time of the peak power value during the last hour.
00:00:00
Time.
N/A
45.26
Hourly total energy
(resettable)
Total energy consumption during the last hour, that is, the
most recent 60 minutes.
You can reset the value by setting it to zero.
0.00 kWh
-3000.00 … 3000.00
kWh
Total energy.
10 = 1 kWh
No.
Name/Value
Description
Default
FbEq 16