326 Parameters
76.23
Start stop level
Defines the stop flux level, that is, the flux level for closing
the brake. The drive uses this value as the flux reference
when the stop command is given and the motor actual
speed is below
21.06
Zero speed limit
.
75 %
0...100 %
Stop flux level in percentage of the motor nominal flux.
1 = 1 %
76.24
Start flux hold time
Defines the hold time for the start flux level as the flux
reference. This hold time makes sure that the start flux
level is active for the time required for the brake to open.
2000 ms
0...10000 ms
Start flux hold time.
1 = 1 ms
76.25
Flux ramp up time
Defines the time for the flux reference to ramp up from the
normal flux level (100%) to the start flux level, and from
the stop flux level to the normal level (100%).
2000 ms
0...10000 ms
Flux ramp-up time.
1 = 1 ms
76.26
Flux ramp down time
Defines the time for the flux reference to ramp down from
the normal flux level (100%) to the stop flux level, and
from the start flux level to the normal level (100%).
2000 ms
0...10000 ms
Flux ramp-down time.
1 = 1 ms
76.27
Flux reference
Shows the crane flux reference in percent of the nominal
flux of the motor.
This parameter is read-only and used in the crane
application for Conical motor control. See section
Conical
motor control
on page
563
.
0 %
0...200 %
Crane flux reference.
1 = 1 %
76.31
Motor speed match
Enables the speed matching function or selects the
source for enable/disable signal.
Not selected
Not selected
The motor speed matching function is disabled.
0
Selected
The motor speed matching function is enabled.
1
DI1
Digital input DI1 (
10.02
DI delayed status
, bit 0)
2
DI2
Digital input DI1 (
10.02
DI delayed status
, bit 0)
3
DI3
Digital input DI1 (
10.02
DI delayed status
, bit 0)
4
DI4
Digital input DI4 (
10.02
DI delayed status
, bit 3)
5
DIO1
Digital input/output DIO1 (
11.02
DIO delayed status
, bit 0) 10
DIO2
Digital input/output DIO2 (
11.02
DIO delayed status
, bit 1) 11
Timed function 1
Bit 0 of
34.01
Timed functions status
18
Timed function 2
Bit 1 of
34.01
Timed functions status
19
Timed function 3
Bit 2 of
34.01
Timed functions status
20
Supervision 1
Bit 0 of
32.01
Supervision status
24
Supervision 2
Bit 1 of
32.01
Supervision status
25
Supervision 3
Bit 2 of
32.01
Supervision status
26
Supervision 4
Bit 3 of
32.01
Supervision status
27
Supervision 5
Bit 4 of
32.01
Supervision status
28
Supervision 6
Bit 5 of
32.01
Supervision status
29
Other
Source selection (see
Terms and abbreviations
).
No.
Name/Value
Description
Default
FbEq 16
ACS380 FW.book Page 326 Friday, May 4, 2018 4:18 PM
ghv Vertriebs-GmbH
| Am Schammacher Feld 47 | 85567 Grafing | T 49 80 92 81 89 0 | [email protected] |
www.ghv.de