Parameters 327
76.32
Motor speed steady
deviation level
Defines the allowed motor speed deviation level (absolute
value) for the steady state operation (motor started and
running).
30.00
0.00....30000.00 rpm
1 = 1
76.33
Motor speed ramp
deviation level
Defines the allowed motor speed deviation level (absolute
value) for the ramping state (acceleration/deceleration)
operation (motor started and running).
70.00
0.00....30000.00 rpm
1 = 1
76.34
Speed match fault
delay
Defines the time delay for generating fault
D105
Speed
match
and warning
D200
Brake slip at standstill2
.
1000 ms
0....30000 ms
1 = 1
90
90 Feedback selection
Motor and load feedback configuration.
See also sections
Rush control
(page
70
) and
Jogging
(page
70
).
90.01
Motor speed for
control
Displays the estimated or measured motor speed that is
used for motor control, ie. final motor speed feedback
selected by parameter
90.41
Motor feedback selection
and filtered by
90.42
Motor speed filter time
.
This parameter is read-only.
-
-32768.00 …
32767.00 rpm
Motor speed used for control.
See par.
46.01
90.02
Motor position
Displays the motor position (within one revolution)
received from the source selected by parameter
90.41
Motor feedback selection
.
This parameter is read-only.
-
0.00000000 …
1.00000000 rev
Motor position.
32767 =
1 rev
90.10
Encoder 1 speed
Displays encoder 1 speed in rpm.
This parameter is read-only.
-
-32768.00 …
32767.00 rpm
Encoder 1 speed.
See par.
46.01
90.11
Encoder 1 position
Displays the actual position of encoder 1 within one
revolution.
This parameter is read-only.
-
0.00000000 …
1.00000000 rev
Encoder 1 position within one revolution.
32767 =
1 rev
90.13
Encoder 1 revolution
extension
Displays the revolution count extension for encoder 1.
With a single-turn encoder, the counter is incremented
when encoder position (parameter
90.11
) wraps around in
the positive direction, and decremented in the negative
direction.
This parameter is read-only.
-
-2147483648…
2147483647
Encoder 1 revolution count extension.
-
No.
Name/Value
Description
Default
FbEq 16
ACS380 FW.book Page 327 Friday, May 4, 2018 4:18 PM
ghv Vertriebs-GmbH
| Am Schammacher Feld 47 | 85567 Grafing | T 49 80 92 81 89 0 | [email protected] |