Parameters 323
DIO1
Digital input/output DIO1 (
11.02
DIO delayed status
, bit 0) 10
DIO2
Digital input/output DIO2 (
11.02
DIO delayed status
, bit 1) 11
Timed function 1
Bit 0 of
34.01
Timed functions status
18
Timed function 2
Bit 1 of
34.01
Timed functions status
19
Timed function 3
Bit 2 of
34.01
Timed functions status
20
Supervision 1
Bit 0 of
32.01
Supervision status
24
Supervision 2
Bit 1 of
32.01
Supervision status
25
Supervision 3
Bit 2 of
32.01
Supervision status
26
Supervision 4
Bit 3 of
32.01
Supervision status
27
Supervision 5
Bit 4 of
32.01
Supervision status
28
Supervision 6
Bit 5 of
32.01
Supervision status
29
Other [bit]
Source selection (see
Terms and abbreviations
).
-
76.03
Limit to limit trigger
type
Selects the Limit to limit control trigger type.
Rising Edge
Rising Edge
Safe and stop limits are handled as pulses. Limit to limit
state machine changes states due to rising edge.
0
Falling edge
Safe and stop limits are handled as pulses. Limit to limit
state machine changes states due to falling edge.
1
Level high
Safe and stop limits are handled as static signals. Limit to
limit state machine changes states due state of high
signal.
2
Level low
Safe and stop limits are handled as static signals. Limit to
limit state machine changes states due state of low signal.
3
Other [bit]
Source selection (see
Terms and abbreviations
).
76.04
Forward stop limit
Selects the source to activate the Forward stop limit
function.
When the you enable the Forward stop command, the
function activates an stop command in the forward
direction, and the drive stops as per the stop mode
defined in the parameter
76.12
.
For more information on the function, see section
Crane
stop limit function
on page
546
.
Not selected
Not selected
Disables the stop limit function if the Limit to limit trigger
type (
76.03
) is Rising edge or Level high.
Enables the function if the trigger type is Falling edge or
Level low.
0
Selected
Enables the stop limit function if the Limit to limit trigger
type (
76.03
) is Rising edge or Level high.
Disables the function if the trigger type is Falling edge or
Level low.
1
DI1
Digital input DI1 (
10.02
DI delayed status
, bit 0)
2
DI2
Digital input DI2 (
10.02
DI delayed status
, bit 1)
3
DI3
Digital input DI3 (
10.02
DI delayed status
, bit 2)
4
DI4
Digital input DI4 (
10.02
DI delayed status
, bit 3)
5
DIO1
Digital input/output DIO1 (
11.02
DIO delayed status
, bit 0) 10
DIO2
Digital input/output DIO2 (
11.02
DIO delayed status
, bit 1) 11
No.
Name/Value
Description
Default
FbEq 16
ACS380 FW.book Page 323 Friday, May 4, 2018 4:18 PM
ghv Vertriebs-GmbH
| Am Schammacher Feld 47 | 85567 Grafing | T 49 80 92 81 89 0 | [email protected] |
www.ghv.de