298 Parameters
Speed
01.01
Motor speed used
is sent as actual value 2. The
scaling is defined by parameter
46.01
Speed scaling
.
4
Frequency
01.06 Output frequency
is sent as actual value 2. The
scaling is defined by parameter
46.02
Frequency scaling
.
5
50.09
FBA A SW transparent
source
Selects the source of the fieldbus status word when
parameter
50.06
FBA A SW sel
is set to
Transparent
mode
.
Not selected
Not selected
No source selected.
-
Other
Source selection (see
Terms and abbreviations
).
-
50.10
FBA A act1
transparent source
When parameter
50.07
FBA A actual 1 type
is set to
Transparent
, this parameter selects the source of actual
value 1 transmitted to the fieldbus network through
fieldbus adapter A.
Not selected
Not selected
No source selected.
-
Other
Source selection (see
Terms and abbreviations
).
-
50.11
FBA A act2
transparent source
When parameter
50.08
FBA A actual 2 type
is set to
Transparent
, this parameter selects the source of actual
value 2 transmitted to the fieldbus network through
fieldbus adapter A.
Not selected
Not selected
No source selected.
-
Other
Source selection (see
Terms and abbreviations
).
-
50.12
FBA A debug mode
This parameter enables debug mode. Displays raw
(unmodified) data received from and sent to fieldbus
adapter A in parameters
50.13
…
50.18
.
Disable
Disable
Debug mode disabled.
0
Fast
Debug mode enabled. Cyclical data update is as fast as
possible which increases CPU load on the drive.
1
50.13
FBA A control word
Displays the raw (unmodified) control word sent by the
master (PLC) to fieldbus adapter A if debugging is
enabled by parameter
50.12
FBA A debug mode
.
This parameter is read-only.
-
00000000h…
FFFFFFFFh
Control word sent by master to fieldbus adapter A.
-
50.14
FBA A reference 1
Displays raw (unmodified) reference REF1 sent by the
master (PLC) to fieldbus adapter A if debugging is
enabled by parameter
50.12
FBA A debug mode
.
This parameter is read-only.
-
-2147483648…
2147483647
Raw REF1 sent by master to fieldbus adapter A.
-
50.15
FBA A reference 2
Displays raw (unmodified) reference REF2 sent by the
master (PLC) to fieldbus adapter A if debugging is
enabled by parameter
50.12
FBA A debug mode
.
This parameter is read-only.
-
-2147483648…
2147483647
Raw REF2 sent by master to fieldbus adapter A.
-
No.
Name/Value
Description
Default
FbEq 16