![ABB ACS380 Series Скачать руководство пользователя страница 368](http://html.mh-extra.com/html/abb/acs380-series/acs380-series_firmware-manual_2560368.webp)
368 Additional parameter data
28.97 Frequency ref unlimited
Real
-500.00 … 500.00
Hz
100 = 1 Hz
28.211 Frequency reference shape
List
0...2
-
1 = 1
30 Limits
30.01 Limit word 1
PB
0000h…FFFFh
-
1 = 1
30.02 Torque limit status
PB
0000h…FFFFh
-
1 = 1
30.11 Minimum speed
Real
-30000.00…30000.00
rpm
100 = 1 rpm
30.12 Maximum speed
Real
-30000.00…30000.00
rpm
100 = 1 rpm
30.13 Minimum frequency
Real
-500.00…500.00
Hz
100 = 1 Hz
30.14 Maximum frequency
Real
-500.00…500.00
Hz
100 = 1 Hz
30.17 Maximum current
Real
0.00…30000.00
A
100 = 1 A
30.18 Torq lim sel
Binary src
-
-
1 = 1
30.19 Minimum torque 1
Real
-1600.0…0.0
%
10 = 1%
30.20 Maximum torque 1
Real
0.0…1600.0
%
10 = 1%
30.21 Min torque 2 source
Analog src
-
-
1 = 1
30.22 Max torque 2 source
Analog src
-
-
1 = 1
30.23 Minimum torque 2
Real
-1600.0…0.0
%
10 = 1%
30.24 Maximum torque 2
Real
0.0…1600.0
%
10 = 1%
30.26 Power motoring limit
Real
0.00…600.00
%
100 = 1%
30.27 Power generating limit
Real
-600.00…0.00
%
100 = 1%
30.30 Overvoltage control
List
0…1
-
1 = 1
30.31 Undervoltage control
List
0…1
-
1 = 1
30.35 Thermal current limitation
List
0...1
-
1 = 1
30.36 Speed limit selection
Binary src
-
-
1 = 1
30.37 Min speed source
Analog src
-
-
1 = 1
30.38 Max speed source
Analog src
-
-
1 = 1
30.203 Deadband forward
Real
0.00...100.00
%
100 = 1%
30.204 Deadband reverse
Real
0.00...100.00
%
100 = 1%
31 Fault functions
31.01 External event 1 source
Binary src
-
-
1 = 1
31.02 External event 1 type
List
0…1
-
1 = 1
31.03 External event 2 source
Binary src
-
-
1 = 1
31.04 External event 2 type
List
0…1
-
1 = 1
31.05 External event 3 source
Binary src
-
-
1 = 1
31.06 External event 3 type
List
0…1
-
1 = 1
31.07 External event 4 source
Binary src
-
-
1 = 1
31.08 External event 4 type
List
0…1
-
1 = 1
31.09 External event 5 source
Binary src
-
-
1 = 1
31.10 External event 5 type
List
0…1
-
1 = 1
31.11 Fault reset selection
Binary src
-
-
1 = 1
31.12 Autoreset selection
PB
0000h…FFFFh
-
1 = 1
31.13 Selectable fault
Real
0000h…FFFFh
-
1 = 1
No.
Name
Type
Range
Unit
FbEq32
ACS380 FW.book Page 368 Friday, May 4, 2018 4:18 PM
ghv Vertriebs-GmbH
| Am Schammacher Feld 47 | 85567 Grafing | T 49 80 92 81 89 0 | [email protected] |