88 Program features
Wiring example
The figure below shows a brake control wiring example. The brake control hardware
and wiring is to be sourced and installed by the customer.
WARNING!
Make sure that the machinery into which the drive with brake
control function is integrated fulfills the personnel safety regulations. Note that
the frequency converter (a Complete Drive Module or a Basic Drive Module, as
defined in IEC/EN 61800-2), is not considered as a safety device mentioned in the
European Machinery Directive and related harmonized standards. Thus, the
personnel safety of the complete machinery must not be based on a specific
frequency converter feature (such as the brake control function), but it has to be
implemented as defined in the application specific regulations.
The brake is controlled by bit 0 of parameter
44.01
Brake control status
. The source
of brake acknowledge (status supervision) is selected by parameter
44.07
Brake
acknowledge selection
. In this example,
• parameter
10.24
RO1 source
is set to
Open brake command
(ie. bit 0 of
44.01
Brake control status
), and
• parameter
44.07
Brake acknowledge selection
is set to
DIO1
.
Motor
M
115/230 VAC
Drive control unit
Mechanical brake
Brake control
hardware
Emergency
brake
XRO1
1 NC
2 COM
3 NO
XD24
XDIO
4 +24VD
5 DIO2
ACS380 FW.book Page 88 Friday, May 4, 2018 4:18 PM
ghv Vertriebs-GmbH
| Am Schammacher Feld 47 | 85567 Grafing | T 49 80 92 81 89 0 | [email protected] |