50 Control macros
96.04 Macro select
1 =
ABB standard
12 =
Alternate
13 =
Motor potenti-
ometer
14 =
PID
22.71 Motor
potentiometer
function
0 =
Disabled
0 =
Disabled
1 =
Enabled
(init at power-
up)
0 =
Disabled
22.73 Motor
potentiometer up
source
0 =
Not
selected
0 =
Not
selected
4 =
DI3
0 =
Not
selected
22.74 Motor
potentiometer
down source
0 =
Not
selected
0 =
Not
selected
5 =
DI4
0 =
Not
selected
23.11 Ramp set
selection
10 =
DIO1
10 =
DIO1
0 =
Acc/Dec
time 1
0 =
Acc/Dec
time 1
28.11 Ext1 frequency
ref1
1 =
AI1 scaled
1 =
AI1 scaled
15 =
Motor
potentiometer
16 =
PID
28.15 Ext1 frequency
ref2
0 =
Zero
0 =
Zero
0 =
Zero
0 =
Zero
28.22 Constant
frequency sel1
4 =
DI3
4 =
DI3
10 =
DIO1
5 =
DI4
28.23 Constant
frequency sel2
5 =
DI4
5 =
DI4
0 =
Always off
0 =
Always off
28.71 Freq ramp set
selection
10 =
DIO1
10 =
DIO1
0
=
Acc/Dec
time 1
0 =
Acc/Dec
time 1
40.07 Process PID
operation mode
0 =
Off
0 =
Off
0 =
Off
2 =
On when
drive running
40.16 Set 1 setpoint 1
source
11 =
AI1
percent
11 =
AI1
percent
11 =
AI1
percent
11 =
AI1
percent
40.17 Set 1 setpoint 2
source
0 =
Not
selected
0 =
Not
selected
0 =
Not
selected
2 =
Internal
setpoint
40.19 Set 1 internal
setpoint sel1
0 =
Not
selected
0 =
Not
selected
0 =
Not
selected
3 =
DI2
40.20 Set 1 internal
setpoint sel2
0 =
Not
selected
0 =
Not
selected
0 =
Not
selected
4 =
DI3
40.32 Set 1 gain
1.00
1.00
1.00
1.00
40.33 Set 1 integration
time
60.0
60.0
60.0
60.0
ACS380 FW.book Page 50 Friday, May 4, 2018 4:18 PM