284 Parameters
Supervision 3
Bit 2 of
32.01 Supervision status
.
26
Supervision 4
Bit 3 of
32.01 Supervision status
.
27
Supervision 5
Bit 4 of
32.01 Supervision status
.
28
Supervision 6
Bit 5 of
32.01 Supervision status
.
29
Other [bit]
Source selection (see
Terms and abbreviations
on page
112
).
-
44.208 Safety close speed
Defines the speed limit for the Brake safe closure function. 50.00 rpm
0.00 …
30000.00 rpm
Brake safe closure speed.
1 = 1 rpm
44.209 Safety close delay
Defines the time delay before the drive trips on fault
D102
Brake safe closure
.
2000 ms
0…30000 ms
Time delay.
1 = 1 ms
44.211 Extended runtime
Defines the time period during which drive keeps the
motor magnetized after the brake is closed. The Extended
run time function is enabled if this value is less than 3600
seconds or greater than 0 seconds.
Note
: The extended run time function is active only when
all these conditions are satisfied:
• the drive is set to vector motor control mode (see page
54
)
• the drive is in Remote control
WARNING!
Extended runtime causes the
motor to heat up. In cases where long
magnetization time is required, make sure to use
motors with external ventilation.
0.0 s
0.0…3600.0 s
Time period.
10 = 1 s
44.212 Extended runtime sw
Shows the status of the Extended runtime function.
This parameter is read-only.
0000h
0000h...FFFFh
Extended runtime status.
-
45
45 Energy efficiency
Settings for the energy saving calculators.
See also section
Energy saving calculators
(page
104
).
45.01
Saved GW hours
Energy saved in GWh compared to direct-on-line motor
connection. This parameter is incremented when
45.02
Saved MW hours
rolls over.
This parameter is read-only (see parameter
45.21
Energy
calculations reset
).
-
0…65535 GWh
Energy savings in GWh.
1 = 1 GWh
No.
Name/Value
Description
Default
FbEq 16
Bit
Name
Description
0
Extended run in operation
0 = Extended run time is active.
1= Extended run time is not active.
1
Extended run enabled
1 = Extended run time function is enabled.
0 = Extended run time function is disabled.
2…15
Reserved
ACS380 FW.book Page 284 Friday, May 4, 2018 4:18 PM