Parameters 153
t
On
=
15.08
RO4 ON delay
t
Off
=
15.09 RO4 OFF delay
0.0 … 3000.0 s
Activation delay for RO4.
1 = 1 s
15.15
RO4 OFF delay
Defines the deactivation delay for relay output RO4. See
parameter
15.14
RO4 ON delay
.
0.0 s
0.0 … 3000.0 s
Deactivation delay for RO4.
1 = 1 s
15.16
RO5 source
Selects a drive signal to be connected to relay output
RO5.
Not
energized
See parameter
15.07
RO2 source
for the available
selections.
15.17
RO5 ON delay
Defines the activation delay for relay output RO5.
0.0 s
t
On
=
15.17 RO3 ON delay
t
Off
=
15.18
RO5 OFF delay
0.0 … 3000.0 s
Activation delay for RO5.
1 = 1 s
15.18
RO5 OFF delay
Defines the deactivation delay for relay output RO5. See
parameter
15.17
RO3 ON delay
.
0.0 s
0.0 … 3000.0 s
Deactivation delay for RO5.
1 = 1 s
19
19 Operation mode
Selection of local and external control location sources
and operating modes.
See section
Operating modes and motor control modes
in
chapter
Program features
.
19.01
Actual operation mode
Displays the operating mode currently used.
See parameters
19.11
…
19.14
.
This parameter is read-only.
-
Zero
Zero.
1
Speed
Speed control (in vector motor control mode).
2
Torque
Torque control (in vector motor control mode).
3
No.
Name/Value
Description
Default
FbEq 16
1
0
1
0
t
On
t
Off
t
On
t
Off
Status of selected
source
RO status
Time
1
0
1
0
t
On
t
Off
t
On
t
Off
Status of selected
source
RO status
Time
ACS380 FW.book Page 153 Friday, May 4, 2018 4:18 PM