Fault tracing 399
A8C0
ULC invalid speed
table
User load curve: X-axis points
(speed) are not valid.
Check that points fulfill conditions. See
parameter
37.11
ULC speed table point
1
.
A8C1
ULC overload warning User load curve: Signal has
been too long over the
overload curve.
See parameter
37.03
ULC overload
actions
.
A8C4
ULC underload
warning
User load curve: Signal has
been too long under the
underload curve.
See parameter
37.04
ULC underload
actions
.
A8C5
ULC invalid underload
table
User load curve: Underload
curve points are not valid.
Check that points fulfill conditions. See
parameter
37.21
ULC underload point 1
.
A8C6
ULC invalid overload
table
User load curve: Overload
curve points are not valid.
Check that points fulfill conditions. See
parameter
37.31
ULC overload point 1
.
A8C8
ULC invalid frequency
table
User load curve: X-axis points
(frequency) are not valid.
Check that points fulfill conditions. -
500.0 Hz <
37.16
<
37.17
<
37.18
<
37.19
<
37.20
< 500.0 Hz. See
parameter
37.16
ULC frequency table
point 1
.
A981
External warning 1
(Editable message text)
Programmable warning:
31.01
External event 1
source
31.02
External event 1
type
Fault in external device 1.
Check the external device.
Check setting of parameter
31.01
External event 1 source
.
A982
External warning 2
(Editable message text)
Programmable warning:
31.03
External event 2
source
31.04
External event 2
type
Fault in external device 2.
Check the external device.
Check setting of parameter
31.03
External event 2 source
.
A983
External warning 3
(Editable message text)
Programmable warning:
31.05
External event 3
source
31.06
External event 3
type
Fault in external device 3.
Check the external device.
Check setting of parameter
31.05
External event 3 source
.
A984
External warning 4
(Editable message text)
Programmable warning:
31.07
External event 4
source
31.08
External event 4
type
Fault in external device 5.
Check the external device.
Check setting of parameter
31.07
External event 4 source
.
A985
External warning 5
(Editable message text)
Programmable warning:
31.09
External event 5
source
31.10
External event 5
type
Fault in external device 5.
Check the external device.
Check setting of parameter
31.09
External event 5 source
.
AF88
Season configuration
warning
You have configured a season
which starts before the
previous season.
Configure the seasons with increasing
start dates, see parameters
34.60
Season 1 start date
…
34.63
Season 4
start date
.
Code
(hex)
Warning / Aux. code
Cause
What to do
ACS380 FW.book Page 399 Friday, May 4, 2018 4:18 PM