Parameters 255
36.50
AL2 reset date
The date on which amplitude logger 2 was last reset.
01/01/1980
1/1/1980...6/5/2159
Last reset date of amplitude logger 2.
-
36.51
AL2 reset time
The time at which amplitude logger 2 was last reset.
00:00:00
-
Last reset time of amplitude logger 2.
-
37
37 User load curve
Settings for user load curve.
See also section
User load curve
(page
75
).
37.01
ULC output status
word
Displays the status of the monitored signal (
37.02
). The
status is shown only while the drive is running. (The status
word is independent of the actions and delays selected by
parameters
37.03
,
37.04
,
37.41
and
37.42
.)
This parameter is read-only.
0000h
0000h…FFFFh
Status of the monitored signal.
1 = 1
37.02
ULC supervision
signal
Selects the signal to be monitored. The function compares
the absolute value of the signal against the load curve.
Motor
torque %
Not selected
No signal selected. Monitoring disabled.
0
Motor speed %
01.03 Motor speed %
.
1
Motor current %
01.08
Motor current % of motor nom
.
2
Motor torque %
01.10
Motor torque
.
3
Output power % of
motor nom
01.15
Output power % of motor nom
.
4
Output power % of
drive nom
01.16
Output power % of drive nom
. 5
Other
Source selection (see
Terms and abbreviations
).
-
37.03
ULC overload actions
Selects how the drive reacts if the absolute value of the
monitored signal stays continuously above the overload
curve for longer than the value of
37.41 ULC overload
timer
.
Disabled
Disabled
No warnings or fault generated.
0
Warning
The drive generates an
A8C1
ULC overload warning
if the
signal has been continuously over the overload curve for a
time defined by parameter
37.41 ULC overload timer
.
1
Fault
The drive trips on
8002
ULC overload fault
if the signal
has been continuously over the overload curve for a time
defined by parameter
37.41 ULC overload timer
.
2
No.
Name/Value
Description
Default
FbEq 16
Bit
Name
Description
0
Under load limit
1 = Signal lower than the underload curve.
1
Within load range
1 = Signal between the underload and overload curve.
2
Overload limit
1 = Signal higher than the overload curve.
3
Outside load limit
1 = Signal lower than the underload curve or higher than the
overload curve.
4…15
Reserved