![ABB ACS380 Series Скачать руководство пользователя страница 525](http://html.mh-extra.com/html/abb/acs380-series/acs380-series_firmware-manual_2560525.webp)
Appendix A - ACS380 in crane applications 525
Input signals
• Fault reset (DI1)
• Control words and reference words through the fieldbus adapter module
Output signals
• Status words and status signals through the fieldbus adapter module
• Brake command (RO1)
Configuring speed feedback using a HTL/TTL pulse encoder
You can configure the speed feedback with a BTAC pulse encoder interface module
(L535). This adds a digital pulse encoder interface to the drive and provides
accurate speed or position (angle) feedback from the motor shaft.
Note:
ABB product offering for cranes highlights safety and performance. You should
use components that increases safety. For example, in hoist crane application drives,
closed loop control (encoder or external supervision) must be used for safe speed
supervision.
The figure below shows the ACS380 drive with BTAC module.
For information related to mechanical and electrical installation, see the hardware
manual of the drive.
Safety
WARNING!
Obey all safety instructions for the drive. Only qualified electricians are
allowed to start up the drive.
Parameter settings
Power up the BTAC module and the drive (if external supply).
Set the feedback selection.
90.41
Motor feedback selection
=
Encoder 1
90.45
Motor feedback fault
=
Fault
Set the number of pulses according to encoder nameplate (
92.10 Pulses/revolution
).
ACS380 FW.book Page 525 Friday, May 4, 2018 4:18 PM