K465i Operations and Maintenance
P/N 1212831 Rev C
Page 5-182
Copyright
©
2012
Veeco Instruments, Inc. Confidential
All Rights Reserved
Figure 5-150. Heater Baseplate Assembly Bottom View
Procedure 5-35: Heater Assembly Removal/Replacement
Removing the Heater Assembly from the Reactor
1.
Locate and shut down the reactor’s electrical connections to the heater assembly (circuit
breaker/power supply switch).
2. Disconnect the heater power supply cables.
3. Locate and disconnect the heater baseplate cooling tube connections to the baseplate.
4. Disconnect the electrode cooling tubes.
5.
Drain all water from the heater’s lines and assembly.
6. Loosen and remove the cap screws on the o-ring retainers for the heater assembly cooling tube (see