K465i Operations and Maintenance
P/N 1212831 Rev C
Page 1-11
Copyright
©
2012
Veeco Instruments, Inc. Confidential
All Rights Reserved
Starting the Tool/Resetting the Button
1. Pull out all of the
EMO
buttons.
2. Push the
RESET
button to reset the
Safety
Relay
.
3. Push the
Flange Handle
up to its
ON
position.
4. Push the
ON
button to start the tool.
5. Move to the
Alarm
buttons, to silence the
Hardware
Audible
Alarm
.
6. The
Alarm
Reset
button lights up, requiring a reset after all hardware alarms are cleared.
The
Process Stop
pushbutton is located on the unit
on a panel with one of the
EMO
pushbuttons.
When the
Process Stop
pushbutton is pushed, all
operations associated with the process or recipe such
as gas flow are inhibited. This is achieved by an input
to the
Programmable Logic Controller,
which is then
interpreted by the software program to inhibit the
necessary operations.
Pushing the
Process Stop
button creates a PLC
shutdown, preventing all valves from being operated.
To enable process or recipe operation, the activated
process pushbutton must be pulled out and then
enabled from the control computer.