Water-Cooling System
The GaN water systems provide a separate cooling water loop to cool:
Flow flange
Shutter assembly
Reactor cooling band
Water-to-water
Heat Exchanger
The
Heat Exchanger
regulates temperature automatically at a desired set-point.
Water flows in and out of
the reactor and its cooling
band to provide
temperature control for the
heater and entire chamber
assembly.
Facility
water and
Heat
Exchanger
water provide
cooling of the reactor
through separate cooling
channels and separate
water pressure
regulators/monitors.
The Heat Exchanger unit
cools facility water,
circulates it through the
reactor’s Heat Exchanger
channel and out to facility
(used) water.
Facility water also flows