R&S NRP
Remote Control - Fundamentals
1144.1400.12 5.17
E-3
Annex: Correspondence between Remote Control and
Manual Control
Table 5-3
compares the control elements of the graphical user interface for manual control with the
SCPI commands for remote control in order to simplify the transfer of manual control procedures to a
remote control program.
Table 5-3: Correspondence between remote control and manual control
Menu item in manual control
SCPI command in short form
Sensor
Æ
Mode
SENS[1..4]:FUNCtion
Sensor
Æ
Mode
Æ
ContAv
Æ
Window
SENS[1..4]:POW:APER
Sensor
Æ
Mode
Æ
ContAv
Æ
Sampling Rate
SENS[1..4]:SAMP
Sensor
Æ
Mode
Æ
ContAv
Æ
DutyCycle
SENS[1..4]:CORR:DCYC
Sensor
Æ
Mode
Æ
ContAv
Æ
DutyCycle
SENS[1..4]:CORR:DCYC:STAT
Sensor
Æ
Mode
Æ
Burst
Æ
Dropout
SENS[1..4]:BURSt:DTOL
Sensor
Æ
Mode
Æ
Burst
Æ
Smoothing of Modulated Signals
SENS[1..4]:SMO:STAT
Sensor
Æ
Mode
Æ
Burst
Æ
Exclude Start
SENS[1..4]:TIM:EXCL:STAR
Sensor
Æ
Mode
Æ
Burst
Æ
Exclude Stop
SENS[1..4]:TIM:EXCL:STOP
Sensor
Æ
Mode
Æ
Timeslot
Æ
No. of Timeslots
SENS[1..4]:POW:TSL:COUN
Sensor
Æ
Mode
Æ
Timeslot
Æ
Nominal Width
SENS[1..4]:POW:TSL:WIDT
Sensor
Æ
Mode
Æ
Timeslot
Æ
Exclude Start
SENS[1..4]:TIM:EXCL:STAR
Sensor
Æ
Mode
Æ
Timeslot
Æ
Exclude Stop
SENS[1..4]:TIM:EXCL:STOP
Sensor
Æ
Mode
Æ
T'gate
Æ
Gate #
SENS[1..4]:SWE:SEL
Sensor
Æ
Mode
Æ
T'gate
Æ
Start of Gate
SENS[1..4]:SWE[1..4]:OFFS:TIME
Sensor
Æ
Mode
Æ
T'gate
Æ
End of Gate
Sum of
SENS[1..4]:SWE[1..4]:OFFS:TIME
and
SENS[1..4]:SWE[1..4]:TIME
Sensor
Æ
Mode
Æ
Scope
Æ
Points
SENS[1..4]:TRAC:POIN
Sensor
Æ
Mode
Æ
Scope
Æ
Realtime
SENS[1..4]:TRAC:REAL
Sensor
Æ
Offset
Æ
Global
SENS[1..4]:CORR:OFFS
SENS[1..4]:CORR:OFFS:STAT