7-47
<l>
The length is set in the length box. Insert the length by using the
Insert
icon. The length is the number of
bytes of the succeeding data (W(1N + 1), 2). The length is automatically set by the CX-Protocol.
(W(1N + 1), 2)
The Inverter’s actual data is to be sent. This example selects
Variable
and
Read R()
and sets the oper-
and. Set
Data
to 1N + 1 because the RUN command data uses four bytes each from D + 3, D + 6, and D +
9.
Set
Edit Length
to 0N + 2 so that it will be set to two bytes.
7-9-5 Ladder Program
•
Transfer the created protocol to the Communications Board.
•
The following example describes how to control the Inverter with this protocol.
•
Before using this program in your system, be sure to check the word and data memory allocations and
change them if necessary so that there will be no word or data memory duplication.
•
This program will stop all communications if a communications error or fault occurs. Be sure to set
n151 for communications time-over detection selection to 0 through 2 so that the system will stop with
time-over detection.
H
Memory Allocations
D
Starting Communications and Status Signals
Word
Functions common to all Slaves
00000
Inverter control communications (continued when set to ON)
00001
Communications error output (on hold when a communications error or fault
occurs)
00002
Communications fault reset
D
Inverter Control Input (Register 0001 RUN Command)
Word
Slave 1 function
Word
Slave 2 function
Word
Slave 3 function
00100
RUN command
00200
RUN command
00300
RUN command
00101
Forward/Reverse
00201
Forward/Reverse
00301
Forward/Reverse
00102
External fault
00202
External fault
00302
External fault
00103
Fault reset
00203
Fault reset
00303
Fault reset
00104
Multi-function input 1
00204
Multi-function input 1
00304
Multi-function input 1
00105
Multi-function input 2
00205
Multi-function input 2
00305
Multi-function input 2
00106
Multi-function input 3
00206
Multi-function input 3
00306
Multi-function input 3
00107
Multi-function input 4
00207
Multi-function input 4
00307
Multi-function input 4
00108
Multi-function input 5
00208
Multi-function input 5
00308
Multi-function input 5
00109
Multi-function input 6
00209
Multi-function input 6
00309
Multi-function input 6
00110
Multi-function input 7
00210
Multi-function input 7
00310
Multi-function input 7
00111
Always set to 0.
00211
Always set to 0.
00311
Always set to 0.
00112
Always set to 0.
00212
Always set to 0.
00312
Always set to 0.
00113
Always set to 0.
00213
Always set to 0.
00313
Always set to 0.
00114
Always set to 0.
00214
Always set to 0.
00314
Always set to 0.
00115
Always set to 0.
00215
Always set to 0.
00315
Always set to 0.
Communications
Chapter 7
Summary of Contents for SYSDRIVE 3G3MV-A2001
Page 1: ...Cat No I527 E1 04 USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter...
Page 2: ......
Page 3: ...USER S MANUAL Multi function Compact Inverter SYSDRIVE 3G3MVSERIES...
Page 18: ......
Page 23: ...Chapter 1 Overview 1 1 Functions 1 2 Nomenclature 1 3 New Features 1...
Page 32: ......
Page 33: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 74: ......
Page 93: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 102: ......
Page 142: ......
Page 242: ......
Page 268: ......
Page 269: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Page 303: ...Chapter 10 List of Parameters 10...
Page 337: ...Chapter 11 Using the Inverter for a Motor 11...
Page 343: ......
Page 344: ...I527 E1 04...