5-8
n015
Middle Output Frequency Voltage
(VC)
Register
010F Hex
Changes during
operation
No
Setting
range
0.1 to 255.0 [0.1 to 510.0] (V)
Unit of
setting
0.1 V
Default setting
12.0
[24.0]
(See
note 2.)
n016
Minimum Output Frequency
(FMIN)
Register
0110 Hex
Changes during
operation
No
Setting
range
0.1 to 10.0 (Hz)
Unit of
setting
0.1 Hz
Default setting
1.5
n017
Minimum Output Frequency
Voltage (VMIN)
Register
0111 Hex
Changes during
operation
No
Setting
range
0.1 to 50.0 [0.1 to 100.0] (V)
Unit of
setting
0.1 V
Default setting
12.0
[24.0]
(See
note 2.)
Note 1.
[ ] values indicate those for 400-V-class Inverters.
Note 2.
For 5.5- and 7.5-kW Inverters, this value is set to 10.0 V for 200-V-class models and to 20.0 V
for 400-V-class models.
Output voltage
(V)
Note
1.
Set the parameters so that the fol-
lowing condition will be satisfied.
n016
x
n014 < n013
x
n011
Note
2.
The value set in n015 will be ignored
if parameters n016 and n014 are the
same in value.
Frequency (Hz)
n012 (VMAX)
n015 (VC)
n017 (VMIN)
n016
(FMIN)
n014
(FB)
n013
(FA)
n011
(FMAX)
•
Set the rated motor frequency as the maximum voltage frequency, and set the rated motor voltage as
the maximum voltage.
•
The vertical-axis load or the load with high viscous friction may require high torque at low speed. If the
torque is insufficient at low speed, increase the voltage in the low-speed range by 1 V, provided that no
overload (OL1 or OL2) is detected. If an overload is detected, decrease the set values or consider the
use of an Inverter model with a higher capacity.
•
The required torque of fan or pump control increases in proportion to the square of the speed. By set-
ting a quadratic V/f pattern to increase the voltage in the low-speed range, the power consumption of
the system will increase.
Basic Operation
Chapter 5
Summary of Contents for SYSDRIVE 3G3MV-A2001
Page 1: ...Cat No I527 E1 04 USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter...
Page 2: ......
Page 3: ...USER S MANUAL Multi function Compact Inverter SYSDRIVE 3G3MVSERIES...
Page 18: ......
Page 23: ...Chapter 1 Overview 1 1 Functions 1 2 Nomenclature 1 3 New Features 1...
Page 32: ......
Page 33: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 74: ......
Page 93: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 102: ......
Page 142: ......
Page 242: ......
Page 268: ......
Page 269: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Page 303: ...Chapter 10 List of Parameters 10...
Page 337: ...Chapter 11 Using the Inverter for a Motor 11...
Page 343: ......
Page 344: ...I527 E1 04...