10-19
Para
me-
ter
No.
Reg-
ister
No.
(Hex)
Name
Description
Set-
ting
range
Unit
of
set-
ting
Defaul
t set-
ting
Chan-
ges dur-
ing
opera-
tion
Ref-
er-
ence
page
n066
0142
Multi-func-
tion analog
output
Selects the monitor item with n065 set to 0.
0: Output frequency (with 10-V output at max.
frequency)
1: Output current (with 10-V output with
Inverter rated output current)
2: Main circuit DC voltage (with 10-V output at
400 [800] V DC)
3: Vector operation torque monitor (with 10-V
output at rated motor torque)
4: Output power (with 10-V output at power
equivalent to max. applicable motor capac-
ity) Cannot be monitored in vector control
mode.
5: Output voltage (with 10-V output at
200 [400] V AC)
* Values in ( ) apply with n067 set to 1.00.
* Values in [ ] are for 400-V models.
0 to 5
1
0
No
5-38
n067
0143
Multi-func-
tion analog
output gain
Used to set the output characteristics of multi-
function analog output.
0.00
to
2.00
0.01
1.00
Yes
5-38
n068
0144
Multi-func-
tion analog
voltage
input gain
Sets the input characteristics of multi-function
analog voltage input.
Gain:Sets the frequency of maximum analog
input (10 V) in percentage based on the
–255
to 255
1%
100
Yes
5-16
n069
0145
Multi-func-
tion analog
voltage
input bias
input (10 V) in percentage based on the
maximum frequency as 100%.
Bias: Sets the frequency of minimum analog
input (0 V) in percentage based on the
maximum frequency as 100%.
–100
to 100
1%
0
Yes
5-16
n070
0146
Multi-func-
tion analog
voltage
input filter
time con-
stant
Sets a primary lag digital filter for multi-function
analog voltage input.
0.00
to
2.00
0.01 s
0.10
Yes
5-17
n071
0147
Multi-func-
tion analog
current
input gain
Sets the input characteristics of multi-function
analog current input.
Gain:Sets the frequency of maximum analog
input (20 mA) in percentage based on the
–255
to 255
1%
100
Yes
5-16
n072
0148
Multi-func-
tion analog
current
input bias
input (20 mA) in percentage based on the
maximum frequency as 100%.
Bias: Sets the frequency of minimum analog
input (4 mA) in percentage based on the
maximum frequency as 100%.
–100
to 100
1%
0
Yes
5-16
n073
0149
Multi-func-
tion analog
current
input filter
time con-
stant
Sets a primary delay digital filter for multi-func-
tion analog current input.
0.00
to
2.00
0.01 s
0.10
Yes
5-17
List of Parameters
Chapter 10
Summary of Contents for SYSDRIVE 3G3MV-A2001
Page 1: ...Cat No I527 E1 04 USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter...
Page 2: ......
Page 3: ...USER S MANUAL Multi function Compact Inverter SYSDRIVE 3G3MVSERIES...
Page 18: ......
Page 23: ...Chapter 1 Overview 1 1 Functions 1 2 Nomenclature 1 3 New Features 1...
Page 32: ......
Page 33: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 74: ......
Page 93: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 102: ......
Page 142: ......
Page 242: ......
Page 268: ......
Page 269: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Page 303: ...Chapter 10 List of Parameters 10...
Page 337: ...Chapter 11 Using the Inverter for a Motor 11...
Page 343: ......
Page 344: ...I527 E1 04...