7-40
Note 1.
The network type refers to the type of the network connected to the Support Software and it
does not refer to the communications configuration between the Programmable Controller
and the 3G3MV Inverter.
Note 2.
The above settings will not be displayed if the Protocol Support Tool is used.
3. Double-click on
New Project
with the left button of the mouse to display
Protocol List.
4. Click on
Protocol List
with the left button of the mouse and click on a blank space with the right
button of the mouse.
5. Select
Create Protocol
.
H
Creating a Sequence
1. Click on
New Protocol
with the left button of the mouse. Then click on a blank space with the right
button of the mouse.
2. Select
Create communication Sequence
.
The following table will appear. Set the parameters related to the sequence in the table.
*
#
Communicat
ion
sequence
Link word
Control
Response
Timer Tr
Timer
Tfr
Timer
Tfs
000
Inverter I/O
Send & Recv
---
Set (Setting
required)
Scan
0.5
0.5
0.5
#
Sequence number. The sequence number is automatically set.
Communication Sequence
The label (name) of the sequence. Input an appropriate, easy-to-distinguish name.
Link Word
Set the area for sharing the data between the Programmable Controller and Communications Board.
Note
In this example, the link word is specified by the operand of the PMCR instruction. Therefore, no
link word is set here.
Control
Set the control method, such as flow control.
Note
Select only model control for communications with the 3G3MV.
Response
A method to write reception data to the I/O memory of the Programmable Controller.
Note
Select “notify by scan” for communications with the 3G3MV.
Communications
Chapter 7
Summary of Contents for SYSDRIVE 3G3MV-A2001
Page 1: ...Cat No I527 E1 04 USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter...
Page 2: ......
Page 3: ...USER S MANUAL Multi function Compact Inverter SYSDRIVE 3G3MVSERIES...
Page 18: ......
Page 23: ...Chapter 1 Overview 1 1 Functions 1 2 Nomenclature 1 3 New Features 1...
Page 32: ......
Page 33: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 74: ......
Page 93: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 102: ......
Page 142: ......
Page 242: ......
Page 268: ......
Page 269: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Page 303: ...Chapter 10 List of Parameters 10...
Page 337: ...Chapter 11 Using the Inverter for a Motor 11...
Page 343: ......
Page 344: ...I527 E1 04...