7-22
Note
There is an OR relationship between input from the control terminals and input through commu-
nications. Therefore, if multi-function inputs of this register are set to forward/stop and reverse/
stop, it is possible to execute the RUN command through the multi-function inputs. These settings
are not, however, recommended because these settings establish two command lines.
D
Inverter Output (Register 0009 Hex)
Bit No.
Function
0
Multi-function contact output (1: ON)
1
Multi-function output 1 (1: ON)
2
Multi-function output 2 (1: ON)
3 to 15
Not used.
Note
The settings will be enabled if multi-function outputs 1 through 3 in n057 through n059 are set to
18 for communications output. Then the corresponding output terminal will be turned ON and
OFF through communications.
H
Broadcast Message with Slave Address: 00 (00 Hex)
Write
Register No.
(Hex)
Function
Description
0000
Not used.
---
0001
RUN command
Refer to the table below.
0002
Frequency reference
Set the frequency reference based on the maximum
frequency as 30,000.
0003 to 000F
Not used.
---
Note 1.
Data can be written to registers 0001 and 0002 only.
Note 2.
No data can be written to multi-function input.
Note 3.
The unit of setting of the broadcast message is different from that in the DSR message to com-
municate with a single Slave.
D
RUN Command (Register 0001 Hex)
Bit No.
Function
0
RUN command (1: RUN)
1
Forward/Reverse (1: Reverse)
2
External fault (1: External fault EF0)
3
Fault reset (1: Fault reset)
4 to 15
Not used.
7-6-2 Monitor Functions
Register No.
(Hex)
Function
Description
0020
Status signal
Refer to the following corresponding table.
0021
Fault status 1
Refer to the following corresponding table.
0022
Data link status
Refer to the following corresponding table.
Communications
Chapter 7
Summary of Contents for SYSDRIVE 3G3MV-A2001
Page 1: ...Cat No I527 E1 04 USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter...
Page 2: ......
Page 3: ...USER S MANUAL Multi function Compact Inverter SYSDRIVE 3G3MVSERIES...
Page 18: ......
Page 23: ...Chapter 1 Overview 1 1 Functions 1 2 Nomenclature 1 3 New Features 1...
Page 32: ......
Page 33: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 74: ......
Page 93: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 102: ......
Page 142: ......
Page 242: ......
Page 268: ......
Page 269: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Page 303: ...Chapter 10 List of Parameters 10...
Page 337: ...Chapter 11 Using the Inverter for a Motor 11...
Page 343: ......
Page 344: ...I527 E1 04...