6-34
and capacity of the motor.) When setting the undertorque detection level, allow for a no-load cur-
rent.
n119
Undertorque detection time
Register
0177 Hex
Changes during
operation
No
Setting
range
0.1 to 10.0 (s)
Unit of
setting
0.1 s
Default setting
0.1 s
Set Values
•
Set the undertorque detection time.
•
The Inverter will detect undertorque when current (or torque) the same as or lower than the detection
level is output for the preset detection time.
Advanced Operation