5-27
Note 1.
The setting unit of acceleration or deceleration time is determined by the set value in n018
(acceleration/deceleration time setting unit).
n018 set to 0 (0.1 s unit): Setting range from 0.0 to 6,000 s (0.0 to 999.9 s or 1,000 to 6,000 s)
n018 set to 1 (0.01 s unit): Setting range from 0.00 to 600.0 s (0.0 to 99.99 s or 100.0 to
600.0 s)
Note 2.
When n018 is set to 1 (0.01 s unit), the default value of acceleration or deceleration time will be
set to 10.00.
H
S-shape Acceleration/Deceleration Characteristic (n023)
•
Trapezoidal and S-shape acceleration and deceleration are available. Using the S-shape characteris-
tic function for acceleration and deceleration can reduce shock to the machinery when stopping or
starting.
•
Any one of three S-shape acceleration/deceleration times (0.2, 0.5, and 1.0 s) is selectable.
n023
S-shape Acceleration/Deceleration
Characteristic
Register
0117 Hex
Changes during
operation
No
Setting
range
0 to 3
Unit of
setting
1
Default setting
0
Set Values
Value
Description
0
No S-shape acceleration/deceleration characteristic (Trapezoidal acceleration/deceleration)
1
S-shape acceleration/deceleration characteristic time is 0.2 s
2
S-shape acceleration/deceleration characteristic time is 0.5 s
3
S-shape acceleration/deceleration characteristic time is 1.0 s
Note
When the S-shape acceleration/deceleration characteristic time is set, the acceleration and
deceleration times will be lengthened according to the S-shape at the beginning and end of accel-
eration/deceleration.
Basic Operation
Chapter 5
Summary of Contents for SYSDRIVE 3G3MV-A2001
Page 1: ...Cat No I527 E1 04 USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter...
Page 2: ......
Page 3: ...USER S MANUAL Multi function Compact Inverter SYSDRIVE 3G3MVSERIES...
Page 18: ......
Page 23: ...Chapter 1 Overview 1 1 Functions 1 2 Nomenclature 1 3 New Features 1...
Page 32: ......
Page 33: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 74: ......
Page 93: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 102: ......
Page 142: ......
Page 242: ......
Page 268: ......
Page 269: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Page 303: ...Chapter 10 List of Parameters 10...
Page 337: ...Chapter 11 Using the Inverter for a Motor 11...
Page 343: ......
Page 344: ...I527 E1 04...